Set Frequency; Set Input - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Set Frequency

The Set Frequency Parameter command sets the frequency stability thresholds for
the specified input. The threshold settings lim1 and lim2 are values in ps/s. The
error mode mod1 and mod2 determine what happens when lim1 and lim2 are
exceeded, respectively. The tmper determines which time period the thresholds and
error conditions apply to. Use aid ALL or <null> to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response

Set Input

The Set Input Parameter command provisions the selected T1/E1 Input module.
Use aid ALL or <null> to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SET-PRMTR-FREQ:[tid]:[aid]:ctag::lim1,mod1,
lim2,mod2, tmper;
INP, INPx, INPx[-y], ALL, <null>
lim1, lim2 = <number>
mod1, mod2 = Fail, Alrm, Rept, Ignr
tmper = 100, 1000, 10000
2
SET-PRMTR-FREQ:TSG3800:INP1:ctag:175,Alrm,200
,Fail,1000;
TSG3800 02-09-11 09:49:07
M 630 COMPLD
;
SET-PRMTR-INPT:[tid]:[aid]:ctag:mode,zs,crc,
freq,term;
INP, INPx, INPx[-y], ALL, <null>
mode: T1 modules: D4, ESF, CLK
E1 modules: CAS, CCS, CLK
zs = On or Off
crc = On or Off
Freq = 1, 1.544, 2.048, 5, 10
term = 50, 75, 100, 120, 3300