Retrieve Alarm Parameters; Retrieve Clock Parameters - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

TL1 Reference
Retrieve Commands

Retrieve Alarm Parameters

The Retrieve Alarm Parameters command reports the error and clear counts as well
as the current mode for the specified error and input port.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Response Format
Example Command
Example Response

Retrieve Clock Parameters

The Retrieve Clock Parameters command reports the settings of the specified Clock
module.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
406 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-PRMTR-AIS:[tid]:[aid]:ctag;
RTRV-PRMTR-BPV:[tid]:[aid]:ctag;
RTRV-PRMTR-CRC:[tid]:[aid]:ctag;
RTRV-PRMTR-LOS:[tid]:[aid]:ctag;
RTRV-PRMTR-OOF:[tid]:[aid]:ctag;
INP, INPx, INPx[-y], ALL, <null>
2
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:prmtr,ercnt,clcnt,mode<cr><lf>
where:
ercnt is the error count
clrcnt is the clear count
mode is Fail|Alrm|Rept|Ignr
RTRV-PRMTR-AIS:TSG:INP2:ctag;
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^TSG:AIS,1,5 ALRM
RTRV-PRMTR-CLK:[tid]:[aid]:ctag;
CLK, CLKA, CLKB, ALL, <null>
2
12778474-002-2 Revision F – March 2004