Configuring The Analog Output Module; Frame Generator Compatibility Jumper Settings - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Configuring the Analog Output Module

This section describes how to configure the Analog Output module to meet the
requirements of your particular installation.
Caution: To prevent ESD damage to the module, always observe the
precautions described in
Setting Jumpers W3 and W5
Use jumpers on W3 and W5 to define the source of the clock signal to be used by
the module. These jumpers also configure the module for compatibility with the
Frame Generator you are using.
Table 7-20. Frame Generator Compatibility Jumper Settings
Frame Generator Clock (MHz)
Clock 1 = 1.544 (default)
Clock 1 = 2.048
Clock 2 = 1.544
Clock 2 = 2.048
Setting the Output Frequency
Jumpers W11-Ch1, W10-Ch2, W9-Ch3, W8-Ch4, W7-Ch5, and W6-Ch6 must be
set to the 1 MHz, 5 MHz, or 10 MHz position. Each channel's output frequency is
independent of the other channels.
Caution: To avoid improper operation of the module, do not change
jumpers W1, W2, and W4.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Properly Handling the
Modules, on page 61.
Table 7-20
describes the appropriate settings.
W3
W5 (MHz)
Clock 1
1.544
Clock 1
2.048
Clock 2
1.544
Clock 2
2.048
Output Modules
Analog Output Module
TSG-3800 User's Guide 233