Functional Description; Single-Port Input Module Indicators - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Input Modules
Single-Port Input Module
Table 5-12
describes the status indicators (LEDs) located on the front panel of the
Single-Port Input module.
Table 5-12. Single-Port Input Module Indicators
Indicator
POWER
REF
MOD FLT
PORT
FAULT PT1

Functional Description

Refer to
Figure 5-7
DS1 signals in SF (D4) or ESF format with or without B8ZS zero suppression. The
input circuits provide DC blocking and transformer isolation for balanced AMI
signals. The termination is user-selectable for 100 ohm (line) or 3.3k ohm (bridging)
at levels of +3 to –24 dBDSX (line). The module monitors and reports occurrences
of loss of signal (LOS), alarm indicator signal (AIS), out of frame (OOF), and bipolar
violations (BPV). In ESF mode the module also monitors and reports CRC errors,
and the synchronous quality level SSM messages in the FDL channel.
152 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Color
GREEN
On = Power is applied
GREEN
On = The Clock Modules are locked to on of the
references applied to this module
RED
On = A non-input signal related fault condition exists
on this module
RED
On = A fault condition exists with the input signal on
this module
for the following functional discussion. The T1 version accepts
Description
12778474-002-2 Revision F – March 2004