Setting the Slip Reset Switch
A slip fault (SLIP) or an output fault (FAULT) can be cleared by pressing the RESET
switch.
Monitors
The DS1 signals can be monitored at the front panel as follows:
EAST IN
EAST OUT (re-timed)
WEST (through)
TIM Bypass Relay Assembly
The TIM Bypass Relay Assembly is plugged into the adjacent output slot of the shelf
to provide an alternate signal path in case the TIM is removed for service. When the
TIM is operational, the relays are opened to allow the signals to be routed through
the re-timing and monitoring functions of the TIM. When the TIM is in "BYPASS"
mode or is removed from the shelf, the relays close, bypassing both the East and
West signal paths from input connections to output connections. The TIM then can
be removed for service without disrupting the signals.

Installing the Timing Insertion Module

The Timing Insertion module is designed to operate singly. Insert the module in a
primary distribution slot. Insert the TIM Bypass Relay Assembly into the
corresponding secondary distribution slot.
secondary distribution slots in the TSG-3800 series.
Table 7-56. Primary and Secondary Distribution Slots
Model
3800/3800E
18, 20
19-inch Shelves
3800 23-inch Shelf
18, 20, 22
3800X/3800EX
4, 6, 8, 10, 12, 14, 16, 18, 20
19-inch Shelves
3800X 23-inch
4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24
Shelf
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Primary Distribution Slots
Timing Insertion Module
Table 7-56
lists the primary and
Secondary Distribution Slots
19,21
19, 21, 23
5, 7, 9, 11, 13, 15, 17, 19, 21
5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25
TSG-3800 User's Guide 285
Output Modules

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents