Retrieve Current Alarms; Retrieve Equipment Condition - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

TL1 Reference
Retrieve Commands

Retrieve Current Alarms

The Retrieve Current Alarms command reports all active alarms from the TSG-3800
or from the selected module. There is no report message for modules or inputs that
are not in alarm. The condscr contains the event identification number as described
in
Table
C-6.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message followed by the alarm message report. If it does not successfully receive
the command, it returns the DENY message.
Command Syntax
Response Format
Valid aid
Minimum User Level
Example Command
Example Response

Retrieve Equipment Condition

The Retrieve Equipment Condition command reports the mode status of the
TSG-3800 or of the selected module or input.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG0-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Response Format
Valid aid
390 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-ALMS:[tid]:[aid]:ctag;
^^^"aid:ntfcncde,condtype,srveff,\"condscr\""
CPU, INPx[-y], CLKA, CLKB, FGA, FGB
1
RTRV-ALMS:TSG:CLKA:ctag;
TSG 02-09-25 03:01:36
M 1 COMPLD"
"A ,00,00,00,00,00"
or
TSG 02-09-15 09:57:25
M 1 COMPLD"
"*C,03,18,"
;
RTRV-COND-EQPT:[tid]:[aid]:ctag;
^^^aid:mode,status<cr><lf>
where Mode for:
CPU is Run|Halt
Clocks is Warm|Hold|ACQ|Lock
FGs is Man|Auto|Bypass
and Status for:
CPU is OK|Pwrfail
Clocks and FGS is Ref|OK|Fail|Dis
CPU, CLK, CLKA, CLKB, FG, FGA, FGB, ALL,
<null>
12778474-002-2 Revision F – March 2004