Retrieve Events

The Retrieve Event command reports the current data for the specified event type.
You can specify an optional time frame (date and time) for the report. Each event
appears on a separate line in the response. All events are displayed if the aid is All
or <null>.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Response Format
Example Command
Example Response
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-EVNT-MSG:tid:[aid]:ctag[::start[:stop]];
RTRV-EVNT-EQPT:tid:[aid]:ctag[::start[:stop]];
RTRV-EVNT-INP:tid:[aid]:ctag[::start[:stop]];
RTRV-EVNT-ALL:tid:[aid]:ctag[::start[:stop]];
INP, INPx, INPx[-y], CLK, CLKA, CLKB, FG, FGA,
FGB, OTP, CPU, ALL, <null>
1
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^"[aid]:ntfcncde,condtype,srveff,ocrdat,ocr
tm [:condscr]"<cr><lf>
RTRV-EVNT-MSG:CLK::ctag;
TSG 02-11-04 19:00:19
M 13 COMPLD
^^^04NOV2002 14:40:03.020 Telnet User A,
DSTREBE, Logged In At Administrator Level
;