Making Signal Connections
The output signals are available at the 50-pin connectors located on the rear panel
of the shelf. Outputs one through ten are used by this module. Refer to
Output Signal

Operational Check

With power applied to the shelf, install the ESF/D4 10-Output module in the
appropriate slot and verify that the POWER indicator is lit. This indicates the module
is receiving power and the module power supply is working.
Check the INPUT FAULT A and INPUT FAULT B indicators. With two functional
Frame Generators installed, both indicators should be off. If one or no Frame
Generator is installed, the appropriate indicator should be lit, indicating the signals
from one or both Frame Generators are missing.
If at least one functional Frame Generator is installed, the OUTPUT FAULT indicator
should go out within eight seconds after the ESF/D4 10-Output module is installed.
If it does not, an output may be bad or has an excessive load connected to it
(example, shorted). The indicator will remain on if there is no reference connected,
since there can be no outputs.
Note: The module indicators may take a few seconds after
installation to reach proper operating status.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Connections, on page 56, for more information.
Output Modules
ESF/D4 10-Output Module
Making
TSG-3800 User's Guide 229

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents