Condition Types; Condition Descriptors - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

<condtype> is the event number correlating to the event. Alarm events use number
1 through 32; all others are non-alarm events.
types for alarms and events.
Table C-3. Condition Types
Condition Type
AIS, BPV, CRC, LOS, OOF, SQL
MTIE, TDEV, FREQ, PHA, REF
INTIFCFAIL
For the SBC firmware build:
INTIFCFAIL = CLK, FG, T1, OTP
OPER, MSG
ADDED, RESTORED, REMOVED
ALARM, PWR, BUS
NA
<condtype> has one or more optional descriptors called <condscr>, which is a text
string that describes the alarm or event, as listed in
Table C-4. Condition Descriptors
Condition Descriptor
srveff
montype
tmper
ocrdat
ocrtm
start
stop
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table C-3
Description
Input signal faults
Input signal limits
Equipment faults
Operator responses
Module operations
CPU Alarm operation
Non-alarm event
Text
SA, NSA
PHA, FREQ, MTIE, TDEV
xHR or ySEC
YY-MM-DD
HH-MM-SS
MM-DD-YY,HH-MM-SS
MM-DD-YY,HH-MM-SS
TL1 Reference
Autonomous Reports
describes the condition
Table
C-4.
Description
Service Affecting or
Not Service Affecting
Type of monitor data
Time period in hours or
seconds
Date of occurrence
Time of occurrence
Start time
Stop time
TSG-3800 User's Guide 377