Retrieve Mtie 2 - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

TL1 Reference
Retrieve Commands

Retrieve MTIE 2

The Retrieve MTIE 2 command reports the true MTIE data from the specified port; it
uses a different output format from the Retrieve MTIE command.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Response Format
Example Command
Example Response
400 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-PD-MTIE2:[tid]:[aid]:ctag[::start][:stop];
INPx[-y]
1
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^"aid:ocrdat,ocrtim,MTIE,tmper,monval[<cr><
lf>
^^^"aid:ocrdat,ocrtim,MTIE,tmper,monval[<cr><
lf>
...
;
where:
ocrdat and ocrtime are the actual date and time the data
were collected
MTIE describes the data that follows
tmper is the data measurement time period in seconds.
Maximum values are 0.05, 0.1, 1.0, 10.0, 100.0, 1000.0
and 10000.0. Only values available in the interval between
the start and stop time are reported.
monval is the data value for the tmper in nanoseconds
RTRV-PD-MTIE2:TSG:INP2-3:ctag;
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^
;
12778474-002-2 Revision F – March 2004