System Messages - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

System Administrator's Reference

System Messages

Who Command
Use this command to display a list of users that are logged on to the TSG-3800.
Level 0
Not applicable
Level 1
WHO
Level 2
Same as level 1 operation
Level 3
Same as level 1 operation
Level 4
Same as level 1 operation
Remarks
None
Related
Restrictions
None
System Messages
Each event may be classified by three parameters. The first parameter is category.
Events may be categorized as Input, Message, Equipment, or Output. Input events
are generated by input signal faults or problems. Equipment events are alarms that
are not generated by input alarms. Message and Output events are information
displayed to the user. Output events are not stored in the event history.
Events may be classified by their alarm level. The alarm level may be critical, major,
minor, or event. Critical, major, and minor correspond to the appropriate alarm level.
Events do not have a corresponding alarm level or are no alarm. This is only
relevant when using TL1.
Events may be further classified by a condition code. The condition code is used in
TL1 to qualify the event. The condition code attempts to give some indication as to
the cause of the event. For example, PHA condition code indicates that the event
was created because of the input phase measurement.
The Condition Type is defined as follows:
AIS, BPV, CRC, LOS, OOF (input signal fault)
MTIE, TDEV, FREQ (input signal limit)
PHA, REF, SQL (input phase/ref /sql fault)
PWR (power fault)
BUS (bus fault)
INTIFCFAIL (equipment faults)
ADDED, RESTORED, REMOVED(module operations)
358 TSG-3800 User's Guide