Set Reference; Set Sql - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Minimum User Level
Example Command
Example Response

Set Reference

The Set Reference command provisions the input reference selection mode.
When the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response

Set SQL

The Set SQL command provisions the Synchronization Quality Level (SQL), the
mode of operation, and selects the bit position (E1 operation only) of the Time Slot 0
word for the SSM input. The Auto mode of operation uses the SQL from the input, if
available; the Prov mode always uses the provisioned level. Use aid ALL or <null>
to specify all inputs.
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2
SET-PRMTR-PRI:TSG3800:INP1:ctag:1;
TSG3800 02-09-11 09:56:42
M 657 COMPLD
;
SET-PRMTR-REF:[tid]::ctag::mode;
none
mode = PRI, BEST, SQL
2
SET-PRMTR-REF:TSG3800::ctag::BEST;
TSG3800 02-09-11 09:57:12
M 658 COMPLD
;
SET-PRMTR-SQL:[tid]:[aid]:ctag::level,
mode[,bit];
INP, INPx, INPx[-y], ALL, <null>
level = PRS, ST2, ST3 DUS, STU
mode = Auto, On, Prov, Off
bit = 4, 5, 6, 7, 8
2
TL1 Reference
Set Commands
TSG-3800 User's Guide 387