Maintenance and Troubleshooting

Troubleshooting Guidelines

Troubleshooting Guidelines
This section provides guidelines for determining and correcting alarm conditions.
Visible signs of failure are the LED indicators and the EIA-232 error messages.
Table 4-1
lists possible causes for alarms, indicators, and corrective action.
Table 4-1. Indicators, Alarms, and Corrective Action
Indicator Lit
Alarm
None
Major
CPU
Major
HOLDOVER
Minor
LOS
Major or
Minor
MAJOR/MINOR;
Major or
no input fault
Minor
indicator lit
NEW REF
OOF
Major or
Minor
OOF and AIS
Major or
MInor
POWER
Minor
(amber indicator)
RUN (off)
Major
SYS
Major
116 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Possible Cause
Module
of Alarm
All
No Power
CPU
Processor
Failure
Clock
Entry into
Holdover
Input
Loss of input
signal
CPU
MTIE errors
Frequency offset
errors
CPU
New reference in
use
Input
Out Of Frame
(OOF)
Input
Alarm Indication
Signal
CPU
Loss of one –48V
supply
CPU
Processor
Failure
CPU
System Failure
Corrective Action
Check power fuse and feeds
See
System and CPU
Alarms, on
page 118
Obtain error message over
EIA-232 port
Check input signal; If input signal
is present, replace Input module
See
Frequency and MTIE
on page 119
Push ACO button to clear
indicator
Check input signal, jumpers,
Monitor, and Module replacement
Check input signal; If input signal
is correct, replace Input module
Check fuse and feed
Note the LED pattern, then call
Symmetricom Global Services.
Remove and re-install the CPU
module. If ineffective, replace the
CPU module.
See
System and CPU
Alarms, on
page 118
12778474-002-2 Revision F – March 2004