12. Remove the fold mirror.
When reinstalling the fold mirror, make sure the reflective surface faces inward.
13. Recalibrate the Measured Color Gamut Data (MCGD) settings. See the CP2215 user manual.

Remove Fold Mirror 2

1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the IOS.
5. Remove one of the 2.5mm screws from each of the three tabs on fold mirror 2.
6. Loosen the remaining 2.5mm screws from each of the three tabs.
7. Hold the mirror in place and swing the tabs out to the side.
8. Carefully lower the mirror to remove it.

Remove the Yellow Notch Filter (YNF)

The YNF is located in the light path just after the contrast aperture.
1. Turn the lamp off and cool the projector for at least 15 minutes.
2. Turn the projector off and then disconnect it from AC power.
3. Remove the top lid. See
4. Remove the front skin. See
5. Loosen and remove the 2 screws securing the yellow notch filter to the IOS.
6. Carefully pull the yellow notch filter away from the IOS toward the front of the projector.
When reinstalling the yellow notch filter, recalibrate MCGD and green primary. See
Filter Color Calibration