340 Fault tracing

Warning messages

Note: The list also contains events that only appear in the Event log.
Code
Warning / Aux. code
(hex)
64FF
Fault reset
A2B1
Overcurrent
A2B3
Earth leakage
Cause
A fault has been reset from the
panel, Drive composer PC tool,
fieldbus or I/O.
Output current has exceeded
internal fault limit.
In addition to an actual
overcurrent situation, this
warning may also be caused
by an earth fault or supply
phase loss.
Drive has detected load
unbalance typically due to
earth fault in motor or motor
cable.
What to do
Event. Informative only.
Check motor load.
Check acceleration times in parameter
group
23 Speed reference ramp
control) or
28 Frequency reference
chain
(frequency control). Also check
parameters
46.01 Speed
Frequency scaling
and
46.03 Torque
scaling.
Check motor and motor cable
(including phasing and delta/star
connection).
Check for an earth fault in motor or
motor cables by measuring the
insulation resistances of motor and
motor cable. See chapter Electrical
installation, section Checking the
insulation of the assembly in the
Hardware manual of the drive.
Check there are no contactors opening
and closing in motor cable.
Check that the start-up data in
parameter group
99 Motor data
corresponds to the motor rating plate.
Check that there are no power factor
correction capacitors or surge
absorbers in motor cable.
Check there are no power factor
correction capacitors or surge
absorbers in motor cable.
Check for an earth fault in motor or
motor cables by measuring the
insulation resistances of motor and
motor cable. See chapter Electrical
installation, section Checking the
insulation of the assembly in the
Hardware manual of the drive. If an
earth fault is found, fix or change the
motor cable and/or motor.
If no earth fault can be detected,
contact your local ABB representative.