Panel Port Communication - ABB ACQ580 Firmware Manual

Pump control program
Hide thumbs Also See for ACQ580:
Table of Contents

Advertisement

No.
Name/Value
47.04
Data storage 4
real32
-2147483.000...
2147483.000
47.11
Data storage 1
int32
-2147483648...
2147483647
47.12
Data storage 2
int32
-2147483648...
2147483647
47.13
Data storage 3
int32
-2147483648...
2147483647
47.14
Data storage 4
int32
-2147483648...
2147483647
47.21
Data storage 1
int16
-32768...32767
47.22
Data storage 2
int16
-32768...32767
47.23
Data storage 3
int16
-32768...32767
47.24
Data storage 4
int16
-32768...32767
49
49 Panel port
communication
49.01
Node ID number
1...32
49.03
Baud rate
38.4 kbps
57.6 kbps
86.4 kbps
115.2 kbps
230.4 kbps
Description
Data storage parameter 4.
32-bit data.
Data storage parameter 9.
32-bit data.
Data storage parameter 10.
32-bit data.
Data storage parameter 11.
32-bit data.
Data storage parameter 12.
32-bit data.
Data storage parameter 17.
16-bit data.
Data storage parameter 18.
16-bit data.
Data storage parameter 19.
16-bit data.
Data storage parameter 20.
16-bit data.
Communication settings for the control panel port on the
drive.
Defines the node ID of the drive. All devices connected to the
network must have a unique node ID.
Note: For networked drives, it is advisable to reserve ID 1 for
spare/replacement drives.
Node ID.
Defines the transfer rate of the link.
38.4 kbit/s.
57.6 kbit/s.
86.4 kbit/s.
115.2 kbit/s.
230.4 kbit/s.
Parameters 239
Def/FbEq16
0.000
-
0
-
0
-
0
-
0
-
0
1 = 1
0
1 = 1
0
1 = 1
0
1 = 1
1
1 = 1
115.2 kbps
1
2
3
4
5

Advertisement

Table of Contents
loading

Table of Contents