ABB ACQ580 Firmware Manual page 364

Pump control program
Hide thumbs Also See for ACQ580:
Table of Contents

Advertisement

360 Fault tracing
Code
Fault / Aux. code
(hex)
0005...0008 Internal error.
000E...0010 Internal error.
FF63
STO diagnostics
failure.
FF81
FB A force trip
FF8E
EFB force trip
Cause
0003 Maximum torque limit too low.
0004 Current measurement
calibration did not finish within
reasonable time
0009 (Asynchronous motors only)
Acceleration did not finish
within reasonable time.
000A (Asynchronous motors only)
Deceleration did not finish
within reasonable time.
000B (Asynchronous motors only)
Speed dropped to zero during
ID run.
000C (Permanent magnet motors
only)
First acceleration did not finish
within reasonable time.
000D (Permanent magnet motors
only)
Second acceleration did not
finish within reasonable time.
0011 (Synchronous reluctance
motors only)
Pulse test error.
0012 Motor too large for advanced
standstill ID run.
0013 (Asynchronous motors only)
Motor data error.
SW internal malfunction.
A fault trip command has been
received through fieldbus
adapter A.
A fault trip command has been
received through the
embedded fieldbus interface.
What to do
Check settings of parameter
Motor nominal
torque, and the torque
limits in group
30
Limits.
Make sure that the maximum torque
limit in force is greater than 100%.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Contact your local ABB
representative.
Check that the motor and drive sizes
are compatible.
Contact your local ABB
representative.
Check that the motor nominal value
settings in the drive are the same as
in the motor nameplate.
Contact your local ABB
representative.
Reboot the control unit (using
parameter
96.08 Control board
or by cycling power.
Check the fault information provided
by the PLC.
Check the fault information provided
by the PLC.
99.12
boot)

Advertisement

Table of Contents
loading

Table of Contents