Parameter Descriptions

3.7 Parameters: 5-** Digital In/Out

3.7.1 5-0* Digital I/O Mode
3
3
Parameters for configuring the input and output using NPN
and PNP.
These parameters cannot be adjusted while motor is
running.
5-00 Digital I/O Mode
Option:
Function:
Digital inputs and programmed digital outputs are pre-
programmable for operation either in PNP or NPN
systems.
PNP Action on positive directional pulses (↕). PNP systems
[0]
*
are pulled down to GND.
NPN Action on negative directional pulses (↕). NPN systems
[1]
are pulled up to + 24 V, internally in the adjustable
frequency drive.
NOTE!
Once this parameter has been changed, it must be activated
by performing a power cycle.
5-01 Terminal 27 Mode
Option:
[0]
Input
*
[1]
Output
5-02 Terminal 29 Mode
Option:
[0]
Input
*
[1]
Output
This parameter is available for FC 302 only.
3.7.2 5-1* Digital Inputs
The digital inputs are used for selecting various functions in
the adjustable frequency drive. All digital inputs can be set
to the following functions:
Digital input function
No operation
Reset
Coast inverse
Coast and Reset Inverse
Quick stop inverse
DC brake inverse
3-48
FC 300 Programming Guide
Function:
Defines terminal 27 as a digital input.
Defines terminal 27 as a digital output.
Function:
Defines terminal 29 as a digital input.
Defines terminal 29 as a digital output.
Select
Terminal
[0]
All *term 32, 33
[1]
All
[2]
All *term 27
[3]
All
[4]
All
[5]
All
MG.33.MA.22 - VLT
Stop inverse
Start
Latched start
Reverse
Start reverse
Enable start forward
Enable start reverse
Jog
Preset reference on
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Slow
Set-up select bit 0
Set-up select bit 1
Precise stop inverse
Precise start, stop
Catch up
Slow-down
Counter input
Pulse input Edge Trigged
Pulse input Time Based
Ramp bit 0
Ramp bit 1
Mains failure inverse
Latched precise start
Latched precise stop
inverse
DigiPot Increase
DigiPot Decrease
DigiPot Clear
Digipot Hoist
Counter A (up)
Counter A (down)
Reset Counter A
Counter B (up)
Counter B (down)
Reset Counter B
Mech. Brake Feedb.
Mech. Brake Feedb. Inv.
PID Error Inv.
PID Reset I-part
PID enable
PTC Card 1
FC 300 standard terminals are 18, 19, 27, 29, 32 and 33. MCB
101 terminals are X30/2, X30/3 and X30/4.
Terminal 29 functions as an output only in FC 302.
®
is a registered Danfoss trademark
[6]
All
[8]
All *term 18
[9]
All
[10]
All *term 19
[11]
All
[12]
All
[13]
All
[14]
All *term 29
[15]
All
[16]
All
[17]
All
[18]
All
[19]
All
[20]
All
[21]
All
[22]
All
[23]
All
[24]
All
[26]
18, 19
[27]
18, 19
[28]
All
[29]
All
[30]
29, 33
[31]
29, 33
[32]
29, 33
[34]
All
[35]
All
[36]
All
[40]
18, 19
[41]
18, 19
[55]
All
[56]
All
[57]
All
[58]
All
[60]
29, 33
[61]
29, 33
[62]
All
[63]
29, 33
[64]
29, 33
[65]
All
[70]
All
[71]
All
[72]
All
[73]
All
[74]
All
[80]
All