Deployment I/O periphery
Pulse train > Proceeding

5.9.2 Wiring

5.9.2.1
Pulse train outputs
X2: DO byte 0
X2
Function
7
DO 0.1
8
DO 0.0
9
0 V
10
DC 24V

5.9.3 Proceeding

Hardware configuration
152
Type
LED
green
red
O
O
I
I
PWM and pulse train output use the same hardware configuration. Switching between
these modes is done within SFB 49. In the Siemens SIMATIC Manager the following
steps should be executed:
1.
Perform a hardware configuration for the CPU.
tion - CPU' page 68
2.
Double-click the counter sub module of the CPU 314C-2 PN/DP.
ð The dialog 'Properties' is opened.
3.
As soon as you select the operating mode for the corresponding channel, a dialog
box with default values for this counter mode is created and shown. For PWM
respectively pulse train output select for the corresponding channel the operating
mode 'Pulse width modulation - PWM' .
4.
Perform the required parameter settings.
5.
Safe your project with 'Station è Safe and compile'.
6.
Transfer your project to your CPU.
Description
Pulse train 1
Pulse train 0
4M: GND for pulse train
LED (red) is on at short circuit respectively overload
4L+: DC 24V power section supply for pulse train
VIPA System MICRO
Ä Chap. 4.4 'Hardware configura-
HB400 | CPU | M13-CCF0000 | en | 18-50