VIPA System MICRO

5.6.4 Parametrization

5.6.4.1
Address assignment
Sub module
Input
address
Counter
816
820
824
828
Sub module
Output
address
Counter
816
820
824
828
HB400 | CPU | M13-CCF0000 | en | 18-50
n
Among others the SFB 47 contains a request interface. Hereby you get read and
write access to the registers of the appropriate counter.
n
So that a new job may be executed, the previous job must have be finished with
JOB_DONE = TRUE.
n
Per channel you may call the SFB in each case with the same instance DB, since the
data necessary for the internal operational are stored here.
n
Writing accesses to outputs of the instance DB is not permissible.
n
Starting, stopping and interrupting a count function of Counter 0 to Counter 2 exclu-
sively happens via the SW gate by setting the SW gate of the SFB 47.
You can also activate input 'Gate 3' via the parametrization for Counter 3.
More information about the usage of this block may be found in the
manual "SPEED7 Operation List" from VIPA.
Access
Description
DINT
Channel 0: Counter value
DINT
Channel 1: Counter value
DINT
Channel 2: Counter value
DINT
Channel 3: Counter value
Access
Description
DWORD
reserved
DWORD
reserved
DWORD
reserved
DWORD
reserved
Deployment I/O periphery
Counting > Parametrization