VIPA System MICRO
User program

5.9.4 Parametrization

5.9.4.1
Address assignment
Sub module
Input
address
Counter
816
820
824
828
Sub module
Output
address
Counter
816
820
824
828
5.9.4.2
Pulse train output
Parameter hardware con-
figuration
HB400 | CPU | M13-CCF0000 | en | 18-50
n
The SFB 49 should cyclically be called (e.g. OB 1) for controlling the pulse train
output.
The SFB 49 is used for PWM and pulse train output.
The switching between the modes takes place by the presetting of the pulse
number (JOB_ID = 08h/09h). As soon as you specify a pulse number > 0, you
switch to the pulse train mode, otherwise PWM is active.
n
The SFB is to be called with the corresponding instance DB. Here the parameters of
the SFB are stored.
Access
Description
DINT
reserved
DINT
reserved
DINT
reserved
DINT
reserved
Access
Description
DWORD
reserved
DWORD
reserved
DWORD
reserved
DWORD
reserved
Default values and structure of this dialog box depend on the selected 'Operating mode' .
For pulse train following parameters are relevant, to be specified or determined:
1
Number of pulses
2
Period duration
3
Pulse duration
4
Pulse pause
Deployment I/O periphery
Pulse train > Parametrization