5.9.5 Status indication

Digital output
DO +0.0
DO +0.1
154
Description
Here specify the range of values for the output. The CPU
hereby determines the pulse duration:
n
Per mil
Output value is within 0 ... 1000
Pulse duration = (Output value / 1000) x period
duration
n
S7 Analog value:
Output value is Siemens S7 analog value 0 ...
27648
Pulse duration = (Output value / 27648) x period
duration
Here you can set the time base, which will apply for resolu-
tion and range of values of the period duration, minimum
pulse duration and on-delay.
n
1ms: The time base is 1ms
n
0.1ms: Time base is 0.1ms
This parameter is ignored.
With period duration you define the length of the output
sequence, which consists of pulse duration and pulse
pause.
Range of values:
Time base 1ms: 1 ... 87ms
Time base 0.1ms: 0.4 ... 87.0ms
With the minimum pulse duration you can suppress short
output pulses and short pulse pauses. All pulses or
pauses, which are smaller than the minimum pulse dura-
tion, are suppressed. This allows you to filter very short
pulses (spikes), which can not be recognized by the
periphery.
Range of values:
Time base 1ms: 0 ... Period duration / 2 * 1ms
Time base 0.1ms: 2 ... Period duration / 2 * 0.1ms
LED
green
Description
Pulse train 0 has "1" signal
Pulse train 0 has "0" signal
Pulse train 1 has "1" signal
Pulse train 1 has "0" signal