Access To The Webvisu; Status Of The Webvisu - YASKAWA VIPA System MICRO Manual

Table of Contents

Advertisement

VIPA System MICRO
10.7.4

Access to the WebVisu

10.7.5

Status of the WebVisu

Status
running
loading webvisu project
shutting down
stop requested
stopped
webvisu feature not activated
webvisu is disabled by the user
no webvisu project file found
no hardware configuration loaded
invalid configuration
internal error: filesystem
webvisu project file too large
HB400 | CPU | M13-CCF0000 | en | 18-50
Via the web server of the CPU, you have access to the device web page and the Web-
Visu, controlled via ports. Access to the WebVisu can be password-protected and
encrypted by means of SSL certificates. If you want to use SSL certificates, you must
integrate them in the SPEED7 Studio accordingly.
n
You can create users via 'Webvisu Project > User administration' , who can access
the WebVisu.
n
Via 'Device properties > WebVisu Configuration' , you can specify the port via which
the WebVisu should be reached and upload security certificates. This changes the
port for accessing the device web page.
HTTP port 8080 (default): The WebVisu can be accessed via the IP address of
the CPU with port number, such as http://192.168.72.120:8080. The device web
page can be accessed via the IP address of the CPU (port 80), such as
http://192.168.72.120.
HTTP port 80: The WebVisu can be accessed via the IP address of the CPU,
such as http://192.168.72.120. The device web page can be accessed via the IP
address of the CPU and port 8080, such as http://192.168.72.120:8080.
SSL port 443 (default): The WebVisu can secure be accessed via the IP address
of the CPU with port number, such as https://192.168.72.120:443. The device
web page can be accessed via the IP address of the CPU and port 8080, such as
http://192.168.72.120:8080.
Please note that the encryption of the communication can affect CPU
performance and therefore the response time of the entire system!
On the device web page at the tab 'WebVisu' via 'Status' you get the status of your
WebVisu project. You can also determine the status at runtime by using the SSL partial
list xy3Eh. More can be found in the manual operation list (HB00_OPL_SP7) of your
CPU.
Meaning
WebVisu is active / has started-up and can be opened
Loading WebVisu project
WebVisu server shuts down
WebVisu STOP requested
WebVisu server is down
WebVisu not activated, memory card is not inserted
WebVisu was disabled by the user
No WebVisu project found
No hardware configuration is loaded
Invalid WebVisu configuration
Error initializing the file system
Error loading WebVisu project, project file too large
Configuration with VIPA SPEED7 Studio
Deployment Web visualization > Status of the WebVisu
253

Advertisement

Table of Contents
loading

Table of Contents