Connecting Service Interface And Profinet - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system, converter, servomotor
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

5.4.6.2

Connecting service interface and PROFINET

Connect your commissioning device using an Ethernet cable to
the service interface (socket X127).
The transmission rates are 10 Mbit/s or 100 Mbit/s.
Connect the converter with PROFINET cables with RJ45 FastConnect connectors or with
PROFINET patch cables (see accessories) via the sockets X150 P1 and X150 P2 to the
PROFINET network.
Table 5-8
Permissible cable length for PROFINET (terminals X150 P1 and X150 P2): 100 m
Permissible cable length for the service interface (terminal X127): 10 m
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
Pin assignment for X127, X150 P1 and X150 P2
Pin
Pin assignment
1
RXP
2
RXN
3
TXP
4
Reserved
5
Reserved
6
TXN
7
Reserved
8
Reserved
5.4 Connecting the converter and the motor
Explanation
Receiving data +
Receiving data -
Sending data +
Sending data -
Installing
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents