Cause:
At least one function module requiring a license is not licensed.
Fault value (r0949, interpret hexadecimal):
Bit x = 1: The corresponding function module does not have a license.
Note:
Assigning bit number to function module, see p0108 or r0108.
Remedy:
- enter and activate the license key for function modules that require a license license (p9920, p9921).
- if necessary, deactivate unlicensed function modules (p0108, r0108).
A13021
Licensing for output frequencies > 550 Hz missing
Reaction:
NONE
Acknowledge:
NONE
Cause:
Configuring the converter results in an output frequency greater than 550 Hz. This function requires a license. The "High
Output Frequency" license is required.
Note:
- in this specific case, the output frequency is limited to 550 Hz.
- the "Trial License" function is not effective for license "High Output Frequency".
Remedy:
- enter and activate the license key for "High Output Frequency" and activate (p9920, p9921).
- if necessary operate the motor below the output frequency of 550 Hz.
A13030
Trial License activated
Reaction:
NONE
Acknowledge:
NONE
Cause:
The "Trial License" function was activated. One of the available periods is expiring.
Remedy:
Not necessary.
The alarm is automatically withdrawn after the periods have expired.
A13031
Trial License period expired
Reaction:
NONE
Acknowledge:
NONE
Cause:
One of the available periods of the "Trial License" function has expired.
Remedy:
- if required, start an additional period (p9918 = 1).
- deactivate functions requiring a license.
- appropriately license the drive unit.
Note:
A license that is not adequate will only become evident after the next time the system runs up.
A13032
Trial License last period activated
Reaction:
NONE
Acknowledge:
NONE
Cause:
The "Trial License" function was activated. The last of the available periods is expiring.
Remedy:
Not necessary.
The alarm is automatically withdrawn after the last period has expired.
A13033
Trial License last period expired
Reaction:
NONE
Acknowledge:
NONE
Cause:
The last period of the "Trial License" function has expired. No additional periods available.