Siemens SINAMICS S210 Operating Instructions Manual page 349

Servo drive system, converter, servomotor
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

The terminals are spring-loaded terminals.
Permissible conductor cross-sections for single-conductor connection or for connecting flexible
cables with or without end sleeves:
● 0.75 mm
● AWG: 18 ... 10
X4: Connector for the external braking resistor
The terminals are spring-loaded terminals.
Permissible conductor cross-sections for single-conductor connection or for connecting flexible
cables with or without end sleeves:
● 0.75 mm
● AWG: 18 ... 10
X107: Connector for the motor holding brake
Phoenix 1745894 FMC 1.5 / 2-ST-3.81, article number 1745894
The terminals are spring-loaded terminals.
Permissible conductor cross-sections:
● For single-conductor cables or for flexible cables with end sleeves without plastic protection:
– 0.25 mm
– AWG: 24 ... 16
● For flexible cables with end sleeves with plastic protection:
– 0.25 mm
– AWG: 24 ... 19
Also connect the conductors for the motor holding brake to the connector at X107, even when
you are using a motor without holding brake.
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
... 6 mm
2
2
Pin
Pin assignment
DCP
Braking resistor, exter‐
nal braking resistor, in‐
ternal
R1
Internal braking resistor
R2
External braking resistor
... 6 mm
2
2
Pin
Pin assignment
BR-
B-
BR+
B+
... 1.5 mm
2
2
... 0.75 mm
2
2
Explanation
If you are using the internal braking resistor, DCP
and R2 must be jumpered. If you are using the
external braking resistor, remove the jumper be‐
tween DCP and R2.
Connect the external braking resistor via the DCP
and R1 terminals.
Explanation
Voltage for motor holding brake, 0 V (white)
Voltage for motor holding brake, 24 V (black)
Ordering data