Technical specifications
10.2 Technical specifications of the converter
Table 10-5
Technical data of the digital inputs
Type
Number
● Low level
● High level
● Current consumption
● Delay time, typ. L → H
● Delay time, typ. H → L
● Electrical isolation
Conductor cross section, max.
314
High-speed digital inputs
for probe or reference
marks
2 (DI 0, DI 1)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
6 mA
5 µs
50 μs
No
1.5 mm²
Failsafe Digital Input
(F-DI)
1 (DI 2 and DI 3)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
5 mA
50 μs
100 µs
Yes
1.5 mm²
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
Digital input for monitoring
the temperature of an ex‐
ternal braking resistor
1 (DI 4)
-30 V ... +5 V
and ≤ 2 mA
15 V ... 30 V
6 mA
5 µs
50 μs
No
1.5 mm²