Permissible ambient conditions

Property
Ambient conditions for transport in the transport packaging
Climatic ambient conditions
Mechanical ambient condi‐
tions
Protection against chemical
substances
Biological environmental
conditions
Ambient conditions for long-term storage in the product packaging
Climatic ambient
conditions
1)
Protection against chemical
substances
Biological environmental
conditions
Ambient conditions in operation
Installation altitude
Climatic ambient conditions
Mechanical ambient condi‐
tions
Protection against chemical
substances
Biological environmental
conditions
Pollution
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
Version
‑40 °C ... +70 °C, according to Class 2K4 to EN 60721‑3‑2
maximum humidity 95 % at 40 °C
Shock and vibration permissible according to 2M3 to EN 60721‑3‑2
Protected according to Class 2C2 to EN 60721‑3‑2
Suitable according to Class 2B2 to EN 60721‑3‑2
‑25 °C ... +55 °C, according to Class 1K4 to EN 60721‑3‑1
Protected according to Class 1C2 to EN 60721‑3‑1
Suitable according to Class 1B2 to EN 60721‑3‑1
● Up to 1000 m above sea level without restrictions
● Up to 4000 m, restrictions, see the following table
● Temperature range: 0 °C ... +50 °C
● Relative humidity: 5 ... 95%, condensation not permitted
● Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing
water and water jets are not permitted
Increased ruggedness regarding temperature range and relative humidity; therefore better
than 3K3 according to EN 60721-3-3
● Vibration levels permissible according to Class 3M2 to EN 60721-3-3
Vibration test in operation according to IEC 60068-2-6 Test Fc (sinusoidal)
9 Hz ... 18 Hz: 1.5 mm deflection amplitude
18 Hz ... 200 Hz: 2 g acceleration amplitude
10 frequency cycles per axis
● Shock permissible according to Class 3M2 to EN 60721-3-3
Shock test in operation according to IEC 60068-2-27 Test Ea (half sinusoidal)
5 g peak acceleration
30 ms duration
3 shocks in all three axes in both directions
Protected according to 3C2 to EN 60721‑3‑3
Suitable according to 3B2 to EN 60721‑3‑3
Suitable for environments with degree of pollution 2 according to EN 61800-5-1