Remedy:
Check the receive configuration data.
For alarm value = 1, 2:
- check the list of the drive objects with process data exchange (p0978). With p0978[x] = 0, all of the following drive objects
in the list are excluded from the process data exchange.
For alarm value = 2:
- check the number of data words for output and input to a drive object.
For alarm value = 17:
- CBE20 Shared Device: Unplug/plug A-CPU.
For alarm value = 223, 500:
- check the setting in p8839 and p8815.
- ensure that only one PZD interface is operated in clock synchronism or with PROFIsafe.
For alarm value = 501:
- check the set PROFIsafe address (p9610).
A08800
PROFIenergy energy-saving mode active
Reaction:
NONE
Acknowledge:
NONE
Cause:
The PROFIenergy energy-saving mode is active
Alarm value (r2124, interpret decimal):
Mode ID of the active PROFIenergy energy-saving mode.
See also: r5600 (Pe energy-saving mode ID)
Remedy:
The alarm is automatically withdrawn when the energy-saving mode is exited.
Note:
The energy-saving mode is exited after the following events:
- the PROFIenergy command end_pause is received from the higher-level control.
- the higher-level control has changed into the STOP operating state.
- the PROFINET connection to the higher-level control has been disconnected.
A09000
Web server user incorrectly configured
Reaction:
NONE
Acknowledge:
NONE
Cause:
An error occurred when configuring the web server user.
Fault value (r0949, interpret decimal):
0: No admin password
1: Invalid admin password
2: Invalid SINAMICS password
Remedy:
Correct the user configuration, enter a correct password.
F13000
License not adequate
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC