Diagnostics

8.1

Status displays and operating elements on the converter

The status of the converter is displayed via the three-digit display as well as by the "RDY" and
"COM" LEDs.
Status display via the three-digit display
Normally, the display is dark.
Faults are shown according to the message classes defined in PROFIdrive. If PROFIdrive
diagnostics is active, then they are simultaneously transferred to the control system.
Detailed information about alarms and faults is provided by the Web server of the converter.
Status display via LEDs
The converter displays the current operating state via two LEDs.
● RDY: converter state
● COM: communication state
During ramp-up, the LEDs assume different states.
The converter is ready for operation when the "RDY" LED is permanently green.
The LEDs always operate independently of one another, except when updating the firmware.
OK button
You can acknowledge the faults whose cause has been corrected with the OK button.
Display and operating elements on the converter
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
Diagnostic functions (Page 232)