5.4.6

Additional connections at 1 AC / 3 AC converters

5.4.6.1

Connecting digital inputs and the external 24 V supply

Connecting the external 24 V supply
Connect a 24 V power supply to the converter.
The terminals are spring-loaded terminals
Permissible cable length: 30 m
Figure 5-24
Permissible conductor cross-sections for single-conductor connection or for connecting flexible
cables with end sleeves:
● 0.2 mm
● AWG: 26 ... 12
Connecting digital inputs
Digital inputs DI 0 and DI 1 are high-speed digital inputs and can be used as measuring inputs.
Digital Inputs DI 2 and DI 3 form a Failsafe Digital Input.
You can connect the temperature monitoring for an external braking resistor to DI 4.
When you use the temperature monitoring function, the converter shuts down the motor if the
external braking resistor temperature becomes too high.
The terminals are spring-loaded terminals
Permissible cable length: 30 m
Figure 5-25
SINAMICS S210 servo drive system
Operating Instructions, 01/2019, A5E41702836B AC
24 V external
Loop-through for additional converters
X124 - 24 V external
... 2.5 mm
2
2
X130 - connector for digital inputs
5.4 Connecting the converter and the motor