Parameters
14.2 List of parameters
Description:
Setting to activate/deactivate measuring probe 1.
The inversion of probe 1 is set in p0490.0.
Value:
0:
210:
Index:
[0] = Encoder 1
[1] = Reserved
[2] = Reserved
Dependency:
See also: p0489, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active
measurement.
Refer to the encoder interface for PROFIdrive.
Note
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
Refer to the encoder interface for PROFIdrive.
p0489[0...2]
Activate measuring probe 2
Can be changed: T, U
Min: 0
Description:
Setting to activate/deactivate measuring probe 2.
The inversion of probe 2 is set in p0490.1.
Value:
0:
211:
Index:
[0] = Encoder 1
[1] = Reserved
[2] = Reserved
Dependency:
See also: p0488, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active
measurement.
Refer to the encoder interface for PROFIdrive.
Note
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
Refer to the encoder interface for PROFIdrive.
p0490
Invert measuring probe
Can be changed: T, U
Min: -
Description:
Setting to invert digital input 0 or 1 (probe 1, 2).
Bit field:
Bit
00
01
Dependency:
See also: p0488, p0489
362
No measuring probe
DI 0 (X130 / 1.2)
No measuring probe
DI 1 (X130 / 1.5)
Signal name
DI 0 (X130 / 1.2)
DI 1 (X130 / 1.5)
Data type: Integer16
Max: 211
Data type: Unsigned32
Max: -
Operating Instructions, 01/2019, A5E41702836B AC
Def: 211
Def: 0000 bin
1 signal
0 signal
Inverted
Not inverted
Inverted
Not inverted
SINAMICS S210 servo drive system