Rotating The Connector At The Motor - Siemens 1FT6031-4AK71-4AH0-Z Manual

Servo motors
Table of Contents

Advertisement

2.6

Rotating the connector at the motor

Rotating the connector at the motor
The DRIVE-CLiQ interface can be rotated but the amount of rotation is limited.
Notice
The permissible range of rotation may not be exceeded.
Do not exceed max. turning torques of 8 Nm.
In order to guarantee the degree of protection, the connector m
10x up to its end stop.
The connector should be rotated using a mating connector attached at the connector thread.
Connecting cables must be secured against tensile stress and bending.
The motors connectors must be secured so that they cannot be rotated any further.
It is not permissible to subject connectors to a continuous force.
Figure 2-6
Connectors can be rotated
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
Electrical Connections
2.6 Rotating the connector at the motor
ay only be rotated a max. of
2-7

Hide quick links:

Advertisement

Table of Contents
loading