Sign In
Upload
Manuals
Brands
HPE Manuals
Server
Integrity NonStop NS2100
HPE Integrity NonStop NS2100 Manuals
Manuals and User Guides for HPE Integrity NonStop NS2100. We have
1
HPE Integrity NonStop NS2100 manual available for free PDF download: Planning Manual
HPE Integrity NonStop NS2100 Planning Manual (128 pages)
Brand:
HPE
| Category:
Server
| Size: 3.5 MB
Table of Contents
Table of Contents
3
About this Document
8
Supported Release Version Updates (Rvus)
8
Intended Audience
8
New and Changed Information in 697513-004R
8
New and Changed Information in 697513-004
8
New and Changed Information in 697513-003
9
New and Changed Information in 697513-002
9
Document Organization
9
Notation Conventions
10
General Syntax Notation
10
Publishing History
12
NS2100 System Overview
13
NS2100 Hardware
14
Example of an NS2100 System, 42U
14
Blade Element (Rx2800 I2)
15
Versatile I/O (VIO) Enclosure
15
Cluster I/O Modules (Clims)
16
CLIM Models and RVU Requirements
16
Storage Cluster I/O Module (CLIM)
17
IP Cluster I/O Module (CLIM) (Optional)
19
DL380 G6 IP CLIM Option 1 - Five Ethernet Copper Ports
19
DL380 G6 IP CLIM Option 2 - Three Ethernet Copper and Two Ethernet Optical Ports
20
Dl380P Gen8 IP CLIM Option 1 - Five Ethernet Copper Ports
20
Dl380P Gen8 IP CLIM Option 2 - Three Ethernet Copper and Two Ethernet Optical Ports
21
Telco Cluster I/O Module (CLIM) (Optional)
21
DL380 G6 Telco CLIM - Five Ethernet Copper Ports
22
Dl380P Gen8 Telco CLIM - Option 1 Five Ethernet Copper Ports
22
CLIM Cable Management Ethernet Patch Panel
23
Dl380P Gen8 Telco CLIM - Option 2 Three Ethernet Copper and Two Ethernet Optical Ports
23
Maintenance Switch
24
SAS Disk Enclosure
24
System Console
24
UPS (Optional)
25
UPS for a Single-Phase Power Configuration (Optional)
25
UPS for a Three-Phase Power Configuration (Optional)
25
Enterprise Storage System - ESS (Optional)
26
ERM (Optional with UPS)
26
Tape Drive and Interface Hardware (Optional)
27
Preparation for Other Hardware
27
Component Location and Identification in an NS2100 System
27
Connections between Storage Clims and ESS
27
Terminology
28
Rack and Offset Physical Location
29
Blade Element Group-Module-Slot Numbering
29
VIO Enclosure Group-Module-Slot Numbering
31
VIO Enclosure Slot Locations, NS2100 System
32
CLIM Connection Group-Module-Slot-Port Numbering
33
DL380 G6 Storage CLIM Connections to VIO Enclosures
33
DL380 G6 IP or Telco CLIM Connections to VIO Enclosures
34
Dl380P Gen8 Storage CLIM Connections to VIO Enclosures
35
System Installation Document Packet
36
Tech Memo for the Factory-Installed Hardware Configuration
36
Dl380P Gen8 IP or Telco CLIM Connections to VIO Enclosures
36
Configuration Forms for the Clims and Servernet Adapters
37
Site Preparation Guidelines for NS2100 Systems
38
Modular Cabinet Power and I/O Cable Entry
38
Emergency Power-Off (EPO)
38
EPO Switches
38
EPO Requirement for NS2100 Systems
38
EPO Requirement for HPE R5000 UPS
38
EPO Requirement for HPE R12000/3 UPS
38
Electrical Power and Grounding Quality
39
Power Quality
39
Grounding Systems
39
Power Consumption
39
Uninterruptible Power Supply (UPS)
40
Cooling and Humidity Control
41
Weight
41
Flooring
41
Dust and Pollution Control
42
Zinc Particulates
42
Space for Receiving and Unpacking the System
42
Operational Space
42
System Installation Specifications for NS2100 Systems
44
Modular Cabinets
44
Power Distribution for NS2100 Systems
44
Power Distribution Units (Pdus)
44
Intelligent PDU Connections (Without UPS)
45
Intelligent PDU Connections (with Single-Phase UPS)
46
Intelligent PDU Connections (with Three-Phase UPS)
47
Modular PDU Connections (Without UPS)
48
Modular PDU Connections (with Single-Phase UPS)
49
AC Power Feeds
50
Modular PDU Connections (with Three-Phase UPS)
50
Example of Bottom AC Power Feed Without UPS
52
Example of Top AC Power Feed Without UPS
53
Example of Top AC Power Feed with Single-Phase UPS
54
Example of Bottom AC Power Feed with Single-Phase UPS
55
Example of Top AC Power Feed with Three-Phase UPS
56
PDU Strapping Configurations
57
Example of Bottom AC Power Feed with Three-Phase UPS
57
Uninterruptible Power Supply (UPS)
58
AC Input Power for Modular Cabinets
58
North America/Japan Single-Phase Power Specifications
58
North America/Japan Three-Phase Power Specifications
59
International Single-Phase Power Specifications
59
International Three-Phase Power Specifications
59
Enclosure AC Input
60
Enclosure Power Loads
60
AC Power Monitoring
62
How OSM Power Failure Support Works
62
Considerations for Ride-Through Time Configuration
63
Considerations for Site UPS Configurations
64
AC Power-Fail States
64
Dimensions and Weights
65
Plan View of the Modular Cabinets
65
Service Clearances for the Modular Cabinets
65
Unit Sizes
65
36U Intelligent Rack Modular Cabinet Physical Specifications
66
42U Modular Cabinet Physical Specifications
66
Enclosure Dimensions
66
Modular Cabinet and Enclosure Weights with Worksheet
67
Modular Cabinet Stability
69
Environmental Specifications
69
Heat Dissipation Specifications and Worksheet
69
Operating Temperature, Humidity, and Altitude
70
Cooling Airflow Direction
71
Nonoperating Temperature, Humidity, and Altitude
71
Tested Electrostatic Immunity
71
Typical Acoustic Noise Emissions
71
Calculating Specifications for Enclosure Combinations
71
Example of Cabinet Load Calculations
71
System Configuration Guidelines for NS2100 Systems
73
Internal Servernet Interconnect Cabling
73
Dedicated Service LAN Cables
73
Length Restrictions for Cables
73
Cable Product Ids
73
Blade Element to VIO Enclosure
73
Processor ID Assignment for the Blade Element
74
SAS Ports to SAS Disk Enclosures
74
SAS Ports to SAS Tape Devices
74
Fibre Channel Ports to ESS
74
Fibre Channel Ports to Tape Devices
74
Storage CLIM Devices
74
Factory-Default Disk Volume Locations for SAS Disk Devices
76
Configuration Restrictions for Storage Clims
76
Configurations for Storage Clims and SAS Disk Enclosures
76
HPE M8381-25 SAS Disk Enclosure, Front and Rear View
76
DL380 G6 Storage CLIM and SAS Disk Enclosure Configurations
77
Two DL380 G6 Storage Clims, Four M8381-25 SAS Disk Enclosures
77
Two DL380 G6 Storage Clims, Two M8381-25 SAS Disk Enclosures
77
Two DL380 G6 Storage Clims, Two M8381-25 SAS Disk Enclosure Configuration
77
Four DL380 G6 Storage Clims, Four M8381-25 SAS Disk Enclosures
78
Two DL380 G6 Storage Clims, Four M8381-25 SAS Disk Enclosure Configuration
78
Dl380P Gen8 Storage CLIM and SAS Disk Enclosure Configurations
79
Four DL380 G6 Storage Clims, Four M8381-25 SAS Disk Enclosure Configuration
79
Two Dl380P Gen8 Storage Clims, Two M8381-25 SAS Disk Enclosures
80
Two Dl380P Gen8 Storage Clims, Two M8381-25 SAS Disk Enclosure Configuration
80
Two Dl380P Gen8 Storage Clims, Four M8381-25 SAS Disk Enclosures
81
Four Dl380P Gen8 Storage Clims, Four M8381-25 SAS Disk Enclosures
81
Two Dl380P Gen8 Storage Clims, Four M8381-25 SAS Disk Enclosure Configuration
81
Four Dl380P Gen8 Storage Clims, Eight M8381-25 SAS Disk Enclosures
82
Four Dl380P Gen8 Storage Clims, Four M8381-25 SAS Disk Enclosure Configuration
82
Four Dl380P Gen8 Storage Clims, Eight M8381-25 SAS Disk Enclosure Configuration
83
VIO Enclosure and Disk Storage Considerations
84
Ethernet to Networks
84
IP CLIM Ethernet Interfaces
84
Telco CLIM Ethernet Interfaces
86
VIO Enclosure Ethernet Ports
87
Hardware Configuration in NS2100 Cabinets
88
Maximum Number of Modular Components, NS2100 System
88
IP and Telco CLIM Coexistence Limits
88
Typical NS2100 Configurations
89
Example 42U Configuration Without UPS and ERM
89
Example 42U Configurations with Possible UPS/ERM Combinations
90
Example 36U Configuration Without UPS and ERM
91
Example 36U Configurations with Possible UPS/ERM Combinations
92
Support and Other Resources
93
Accessing Hewlett Packard Enterprise Support
93
Accessing Updates
93
Websites
94
Customer Self Repair
94
Remote Support
94
Documentation Feedback
94
A Maintenance and Support Connectivity
95
Dedicated Service LAN
95
Fault-Tolerant LAN Configuration
96
DHCP, TFTP, and DNS Window-Based Services
97
Example of a Fault-Tolerant LAN Configuration
97
IP Addresses
98
Ethernet Cables
99
SWAN Concentrator Restrictions
99
Dedicated Service LAN Links
99
Dedicated Service LAN Links with Two VIO Enclosures
99
Dedicated Service LAN Links with IP Clims
100
Dedicated Service LAN Links with Telco Clims
100
Additional Configuration for OSM
101
Initial Configuration for a Dedicated Service LAN
101
System Consoles for NS2100 Systems
101
Primary and Backup System Console Managing One System
101
System Console Configurations
101
Primary and Backup System Consoles Managing Multiple Systems
102
B Cables
103
Cable Types, Connectors, Lengths, and Product Ids
103
Cable Length Restrictions
104
C Operations and Management Using OSM Applications
106
System-Down OSM Low-Level Link
106
D Default Startup Characteristics and Naming Conventions
108
Default Naming Conventions
109
E UPS and Data Center Power Configurations
111
Supported UPS Configurations
111
Nonstop System with a Fault-Tolerant Data Center
112
Nonstop System with a Rack-Mounted UPS
113
SAS Disk Enclosures with a Rack-Mounted UPS
114
Non-Supported UPS Configurations
115
Nonstop System with a Data Center UPS, Single Power Rail
116
Nonstop System with Data Center UPS, both Power Rails
117
Nonstop System with Rack-Mounted UPS and Data Center UPS in Parallel
119
Nonstop System with Two Rack-Mounted UPS in Parallel
121
Nonstop System with Cascading Rack-Mounted UPS and Data Center UPS
122
Nonstop System with Cascading UPS
122
F Warranty and Regulatory Information
124
Warranty Information
124
Regulatory Information
124
Belarus Kazakhstan Russia Marking
124
Turkey Rohs Material Content Declaration
125
Ukraine Rohs Material Content Declaration
125
Index
126
Advertisement
Advertisement
Related Products
HPE FlexNetwork NJ5000 5G PoE Plus Walljack
HPE FlexNetwork NJ5000
HPE Nimble Storage HF Series
HPE 3PAR StoreServ
HPE AH395-9013J
HPE AlphaServer 300
HPE AlphaServer 8200
HPE AlphaServer 8400
HPE Apollo 2000
HPE Apollo 4200
HPE Categories
Server
Switch
Network Router
Wireless Access Point
Storage
More HPE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL