Special Internal Relays

Special internal relays M8000 through M8077 are read/write internal relays used for controlling the CPU operation and
communication. Special internal relays M8080 through M8157 are read-only internal relays primarily used for indicating
the CPU statuses. All special internal relays cannot be used as destinations of advanced instructions.
Internal relays M300 through M315 are used to read input operand statuses of the IOREF (I/O refresh) instruction.
• Do not change the status of reserved special internal relays, otherwise the
Caution
operate correctly.
Special Internal Relay Allocation Numbers (Read/Write)
Allocation
Number
M8000
Start Control
M8001
1-sec Clock Reset
M8002
All Outputs OFF
M8003
Carry (Cy) or Borrow (Bw)
M8004
User Program Execution Error
M8005
Data Link Communication Error
M8006
Data Link Communication Prohibit Flag (Master Station)
Data Link Communication Initialize Flag (Master Station)
M8007
Data Link Communication Stop Flag (Slave Station)
M8010
Status LED
M8011
HMI Write Prohibit Flag
M8012
HMI Operation Prohibit Flag
M8013
Calendar/Clock Data Write/Adjust Error Flag
M8014
Calendar/Clock Data Read Error Flag
M8015
Calendar/Clock Data Read Prohibit Flag
M8016
Calendar Data Write Flag
M8017
Clock Data Write Flag
M8020
Calendar/Clock Data Write Flag
M8021
Clock Data Adjust Flag
M8022
User Communication Receive Instruction Cancel Flag (Por t 1)
M8023
User Communication Receive Instruction Cancel Flag (Por t 2)
M8024
BMOV/WSFT Executing Flag
M8025
Maintain Outputs While CPU Stopped
M8026
Expansion Data Register Data Writing Flag (Preset Range 1)
M8027
Expansion Data Register Data Writing Flag (Preset Range 2)
M8030
High-speed Counter 1 (I0-I2) Comparison Output Reset
M8031
High-speed Counter 1 (I0-I2) Gate Input
M8032
High-speed Counter 1 (I0-I2) Reset Input
M8033
M8034
High-speed Counter 2 (I3) Comparison Output Reset
M8035
High-speed Counter 2 (I3) Gate Input
M8036
High-speed Counter 2 (I3) Reset Input
M8037
M8040
High-speed Counter 3 (I4) Comparison Output Reset
M8041
High-speed Counter 3 (I4) Gate Input
M8042
High-speed Counter 3 (I4) Reset Input
M8043
M8044
High-speed Counter 4 (I5-I7) Comparison Output Reset
Description
— Reserved —
— Reserved —
— Reserved —
« FC4A M
S
U
'
ICRO
MART
SER
S
6: A
CPU Stopped
M
»
ANUAL
N
LLOCATION
UMBERS
may not
MicroSmart
Power OFF
Maintained
Maintained
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Maintained
Cleared
Cleared
Operating
Cleared
Maintained
Cleared
Maintained
Cleared
Operating
Cleared
Operating
Cleared
Maintained
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Cleared
Cleared
Cleared
Cleared
Maintained
Maintained
Maintained
Cleared
Operating
Maintained
Operating
Maintained
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Cleared
Cleared
Maintained
Cleared
Maintained
Cleared
Cleared
Cleared
6-7