IDEC FC4A-C10R2 User Manual page 172

Fc4a series microsmart micro programmable logic controller
Table of Contents

Advertisement

6: A
N
LLOCATION
UMBERS
Allocation
Number
M8045
High-speed Counter 4 (I5-I7) Gate Input
M8046
High-speed Counter 4 (I5-I7) Reset Input
M8047
M8050
Modem Mode (Originate): Initialization String Star t
M8051
Modem Mode (Originate): ATZ Start
M8052
Modem Mode (Originate): Dialing Star t
M8053
Modem Mode (Disconnect): Disconnect Line Star t
M8054
Modem Mode (General Command): AT Command Star t
M8055
Modem Mode (Answer): Initialization String Star t
M8056
Modem Mode (Answer): ATZ Start
M8057
Modem Mode AT Command Execution
M8060
Modem Mode (Originate): Initialization String Completion
M8061
Modem Mode (Originate): ATZ Completion
M8062
Modem Mode (Originate): Dialing Completion
M8063
Modem Mode (Disconnect): Disconnect Line Completion
M8064
Modem Mode (General Command): AT Command Completion
M8065
Modem Mode (Answer): Initialization String Completion
M8066
Modem Mode (Answer): ATZ Completion
M8067
Modem Mode Operational State
M8070
Modem Mode (Originate): Initialization String Failure
M8071
Modem Mode (Originate): ATZ Failure
M8072
Modem Mode (Originate): Dialing Failure
M8073
Modem Mode (Disconnect): Disconnect Line Failure
M8074
Modem Mode (General Command): AT Command Failure
M8075
Modem Mode (Answer): Initialization String Failure
M8076
Modem Mode (Answer): ATZ Failure
M8077
Modem Mode Line Connection Status
Special Internal Relay Allocation Numbers (Read Only)
Allocation
Number
Data Link Slave Station 1 Communication Completion Relay (Master Station)
M8080
Data Link Communication Completion Relay (Slave Station)
M8081
Data Link Slave Station 2 Communication Completion Relay
M8082
Data Link Slave Station 3 Communication Completion Relay
M8083
Data Link Slave Station 4 Communication Completion Relay
M8084
Data Link Slave Station 5 Communication Completion Relay
M8085
Data Link Slave Station 6 Communication Completion Relay
M8086
Data Link Slave Station 7 Communication Completion Relay
M8087
Data Link Slave Station 8 Communication Completion Relay
M8090
Data Link Slave Station 9 Communication Completion Relay
M8091
Data Link Slave Station 10 Communication Completion Relay
M8092
Data Link Slave Station 11 Communication Completion Relay
M8093
Data Link Slave Station 12 Communication Completion Relay
M8094
Data Link Slave Station 13 Communication Completion Relay
M8095
Data Link Slave Station 14 Communication Completion Relay
M8096
Data Link Slave Station 15 Communication Completion Relay
M8097
Data Link Slave Station 16 Communication Completion Relay
6-8
Description
— Reserved —
Description
« FC4A M
S
U
'
ICRO
MART
SER
M
»
S
ANUAL
CPU Stopped
Power OFF
Maintained
Cleared
Maintained
Cleared
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
Maintained
Cleared
CPU Stopped
Power OFF
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared
Operating
Cleared