Programming Windldr - IDEC FC4A-C10R2 User Manual

Fc4a series microsmart micro programmable logic controller
Table of Contents

Advertisement

27: M
M
ODEM
ODE

Programming WindLDR

The Communication page in the Function Area Settings must be programmed to enable the modem communication for
port 2. If required, communication parameters of the CPU module port 2 can also be changed.
Since these settings relate to the user program, the user program must be downloaded to the
any of these settings.
1. From the
WindLDR
appears.
2. Click the Communication tab, and select Modem Protocol in the Port 2 pull-down list.
3. Click the Configure button. The Communication Parameters dialog box appears. Change settings, if required.
The default communication parameters shown below are recommended.
Baud rate
Start bit
Data bits
Parity
Stop bit
Total
4. Click the OK button.
27-10
menu bar, select Configure > Function Area Settings. The Function Area Setting dialog box
9600 bps
Only when the modem connected on the communication line uses differ-
ent communication parameters than the default values of the
1
set the matching communication parameters. Since the total of modem
7
communication parameters is 10 bits, set the value to a total of 10 bits.
Even
1
10 bits
« FC4A M
Baud Rate (bps)
Data Bits
Parity
Stop Bits
Receive Timeout (ms)
Device Number
S
U
'
M
ICRO
MART
SER
S
ANUAL
MicroSmart
1200, 2400, 4800, 9600, 19200
7 or 8
None, Odd, Even
1 or 2
10 to 2540 (10-ms increments)
(Receive timeout is disabled when 2550
is selected.)
0 to 31
»
after changing
,
MicroSmart

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents