NTELLIGENT
Introduction
Intelligent module access instructions are used to read or write data between the CPU module and a maximum of seven
intelligent modules while the CPU module is running or when the CPU module is stopped.
Upgrade Information
Upgraded CPU modules can use the intelligent module access instructions. Applicable CPU modules and system program
version are shown in the table below. For the procedure to confirm the system program version of the CPU module, see
page 29-1.
CPU Module
System Program Version
Use
ver. 4.50 or higher to program the intelligent module access instructions.
WindLDR
Intelligent Module Access Overview
The Run Access Read instruction reads data from the designated address in the intelligent module and stores the read data
to the designated operand while the CPU module is running. The Run Access Write instruction writes data from the desig-
nated operand to the designated address in the intelligent module while the CPU module is running.
The Stop Access Read instruction reads data from the designated address in the intelligent module and stores the read data
to the designated operand when the CPU module is stopped. The Stop Access Write instruction writes data from the desig-
nated operand to the designated address in the intelligent module when the CPU module is stopped.
Data movement while the CPU module is running
ON
RUNA(*)
READ
OFF
RUNA(*)
READ
ON
RUNA(*)
WRITE
OFF
RUNA(*)
WRITE
STPA(*)
READ
STPA(*)
WRITE
Data movement when the CPU module is stopped
OFF
RUNA(*)
READ
OFF
RUNA(*)
WRITE
STPA(*)
READ
STPA(*)
WRITE
M
ODULE
All-in-One Type
FC4A-C10R2
FC4A-C16R2
FC4A-C10R2C
FC4A-C16R2C
******
******
******
******
******
******
******
******
******
******
« FC4A M
S
ICRO
MART
A
CCESS
FC4A-C24R2
FC4A-C24R2C
204 or higher
Intelligent Module
Read
Write
Intelligent Module
Read
Write
U
'
M
»
SER
S
ANUAL
I
NSTRUCTIONS
Slim Type
FC4A-D20RK1
FC4A-D20K3
FC4A-D20RS1
FC4A-D20S3
FC4A-D40K3
FC4A-D40S3
204 or higher
203 or higher
While the CPU module is running
and the input is on, RUNA READ is
executed to read data from the
intelligent module, and RUNA
WRITE to write data to the intelli-
gent module.
When the CPU module is stopped,
STPA READ is executed to read
data from the intelligent module,
and STPA WRITE to write data to
the intelligent module.