Troubleshooting Diagram 10
Data is not transmitted correctly
in the user communication mode.
Are communication
parameters set correctly
Is the data register
designated as transmit status
more than 5 TXD instructions on
the busy signal at the remote
terminal less than
sure of source 1 operand of the
Call IDEC for assistance.
When the user communication still has a problem after completing the above procedure,
also perform the procedure of Diagram 9 described on the preceding page.
using WindLDR?
YES
used repeatedly?
NO
Are inputs to
simultaneously?
NO
Is duration of
5 sec?
YES
Did you make
TXD instruction?
YES
« FC4A M
Set the communication parameters to
NO
match those of the remote terminal using
WindLDR (see page 17-5).
YES
Correct the program to replace the duplicate
data register with a different data register.
Correct the program to make sure that
YES
inputs to more than 5 TXD instructions do
not go on simultaneously.
NO
Make sure that the busy signal at the
remote terminal does not exceed 5 sec.
NO
Make sure that the transmit data desig-
nated as source 1 operand is correct.
S
U
'
M
ICRO
MART
SER
S
ANUAL
29: T
ROUBLESHOOTING
»
29-17