IDEC FC4A-C10R2 User Manual page 183

Fc4a series microsmart micro programmable logic controller
Table of Contents

Advertisement

I/O Expansion for Slim Type CPU Modules
All slim type CPU modules can connect a maximum of seven expansion I/O modules including analog I/O modules.
The expandable I/O points and the maximum total I/O points vary with the type of CPU module as listed below.
Allocation Numbers (Slim Type CPU Modules)
Operand
Input (I)
Expansion Input (I)
Output (Q)
Expansion Output (Q)
Maximum Total
I/O Points
Example:
Slot No.:
20-I/O Type
CPU Module
12-pt Input
8-pt Output
or
40-I/O Type
CPU Module
24-pt Input
16-pt Output
The system setup shown above will have I/O operand numbers allocated for each module as follows:
Slot No.
40-I/O Type CPU Module
1
32-pt Output Module
2
16-pt Input Module
3
16/8-pt Mixed I/O Module
4
8-pt Input Module
5
Analog I/O Module
6
4/4-pt Mixed I/O Module
7
32-pt Input Module
The I/O numbers of the CPU module start with I0 and Q0. The I/O numbers of the expansion I/O modules start with I30
and Q30. When an I/O module is mounted next to a 4/4-point mixed I/O module, note that the allocation numbers skip
four points as shown above.
Input and output modules may be grouped together for easy identification of I/O numbers. When the I/O modules are relo-
cated, the I/O numbers are renumbered automatically.
FC4A-D20K3
FC4A-D20S3
Allocation No.
Points
I0 - I7
12
I10 - I13
128
I30 - I187
(140 total)
Q0 - Q7
8
128
Q30 - Q187
(136 total)
148
1
2
Output
Input
Mixed
Module
Module
I/O
Module
32-pt
16-pt
16-pt
Output
Input
Input
8-pt
Output
Expansion I/O Modules (7 maximum)
Module
« FC4A M
FC4A-D20RK1
FC4A-D20RS1
Allocation No.
I0 - I7
I10 - I13
I30 - I307
Q0 - Q7
Q30 - Q307
244
3
4
5
Input
Analog
Module
I/O
Module
8-pt
Input
I0 to I7, I10 to I17, I20 to I27, Q0 to Q7, Q10 to Q27
Q30 to Q37, Q40 to Q47, Q50 to Q57, Q60 to Q67
I30 to I37, I40 to I47
I50 to I57, I60 to I67, Q70 to Q77
I70 to I77
See page 24-8.
I80 to I83, Q80 to Q83
I90 to I97, I100 to I107, I110 to I117, I120 to I127
S
U
'
M
ICRO
MART
SER
S
ANUAL
6: A
LLOCATION
FC4A-D40K3
FC4A-D40S3
Points
Allocation No.
I0 - I7
12
I10 - I17
I20 - I27
224
I30 - I307
(236 total)
Q0 - Q7
8
Q10 - Q17
224
Q30 - Q307
(232 total)
6
7
Mixed
Input
I/O
Module
Module
4-pt
32-pt
Input
Input
4-pt
Output
I/O Operand Numbers
»
N
UMBERS
Points
24
224
(248 total)
16
224
(240 total)
264
6-19

Hide quick links:

Advertisement

Table of Contents
loading