IDEC FC4A-C10R2 User Manual page 457

Fc4a series microsmart micro programmable logic controller
Table of Contents

Advertisement

Status LEDs
The operation modes of the AS-Interface master module can be changed by pressing the pushbuttons on the front of the
AS-Interface master module or by executing ASI commands. The operation modes can be confirmed on the six status
LEDs on the AS-Interface master module. For details about the ASI commands, see page 28-28.
Status LED Indication
Status LED
Normal Protected Mode
Normal Protected Offline
Connected Mode
Normal Protected
Data Exchange Off
Protected Mode
Local Mode
Configuration Mode
*1: Goes off when AS-Interface power is not supplied.
*2: Goes on when an error is found on the AS-Interface bus.
Address LEDs and I/O LEDs
The operating status and I/O status of each slave can be monitored on the address LEDs and I/O LEDs on the front of the
AS-Interface master module.
Slave Operating Status
The operating status of each slave can be determined by viewing the address LEDs and I/O LEDs.
Address LED
ON
ON
Flash
OFF
Slave I/O Status
The I/O status of each slave can be monitored on the address LEDs and I/O LEDs. Use the short press to change the slave
address when monitoring slave I/O status on the AS-Interface master module. A short press on PB1 increments the
address. At the last address (31B), another short press will return to the first address (0A). A short press on PB2 decre-
ments the address. At the first address (0A), another short press will return to the last address (31B).
The figures below illustrate what happens when you press the PB1 button while the address LEDs indicate 25A. The
address LEDs increment to 26A where a slave is assigned. Note that the address LEDs flash if no slave is assigned.
Monitoring Slave Address 25A
Address LEDs are flashing since
no slave is assigned.
I/O LED
ON or OFF
The slave at this address is active.
Flash
The slave at this address is active, but has an error.
OFF
This address is not assigned a slave.
The AS-Interface bus communication is disabled because the AS-Interface power
OFF
is not supplied or the AS-Interface master module is in normal protected offline.
Short press
on PB1
« FC4A M
28: AS-I
PWR
FLT
*1
*2
ON
OFF
*1
ON
ON
*1
ON
ON
*1
*2
ON
OFF
*1
*2
ON
OFF
Description
I/O LEDs
indicate statuses
S
U
'
M
ICRO
MART
SER
S
ANUAL
M
NTERFACE
ASTER
LMO
CMO
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
Monitoring Slave Address 26A
Address LEDs go on and I/O
LEDs indicate the statuses.
»
C
OMMUNICATION
OFF
CNF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Flash
28-17