29: T
ROUBLESHOOTING
Troubleshooting Diagram 7
Cannot stop or reset operation.
Is stop or
reset input designated in
the WindLDR Function Area
Settings?
Is the designated stop or
reset input on?
Monitor the designated stop or
reset input using WindLDR on a
computer.
Does the monitored
input turn on and off?
Call IDEC for assistance.
29-14
NO
YES
NO
YES
NO
YES
« FC4A M
Note: To monitor M8000, from the WindLDR menu bar,
select Online > Monitor, then Online > Direct Monitor.
Enter M8000 in the Direct Monitor Dialog.
Turn on the designated input.
The input circuit in the CPU mod-
ule is damaged.
Replace the CPU module.
Note: To turn off M8000, from the WindLDR menu bar, select
Online > Monitor, then Online > Direct Set/Reset. Enter
M8000 in the Direct Set/Reset Dialog. Click Reset.
S
U
'
M
ICRO
MART
SER
S
ANUAL
Monitor the star t control special
internal relay M8000 using
WindLDR on a computer.
YES
Is M8000 off?
NO
Turn off the start control special
internal relay M8000 using
WindLDR on a computer.
»