IDEC FC4A-C10R2 User Manual page 24

Fc4a series microsmart micro programmable logic controller
Table of Contents

Advertisement

2: M
S
ODULE
PECIFICATIONS
Function Specifications (All-in-One Type CPU Module)
CPU Module Specifications
CPU Module
Program Capacity
Expandable I/O Modules
Input
I/O Points
Output
User Program Storage
Backup Duration
Backup Data
Battery
RAM Backup
Charging Time
Battery Life
Replaceability
Control System
Instruction Words
Basic instruction
Processing
Time
END processing
Internal Relay
Shift Register
Data Register
Counter
(adding, dual pulse reversible,
up/down selection reversible)
Timer
(1-sec, 100-ms, 10-ms, 1-ms)
Input Filter
Catch Input
Interrupt Input
Self-diagnostic Function
Start/Stop Method
System Statuses at Stop, Reset, and Restart
Mode
Run
Stop (Stop input ON)
Reset (Reset input ON)
Restart
2-4
FC4A-C10R2
FC4A-C10R2C
4,800 bytes
(800 steps)
6
4
EEPROM
Approx. 30 days (typical) at 25°C after backup battery fully charged
Internal relay, shift register, counter, data register
Lithium secondary battery
Approx. 24 hours for charging from 0% to 90% of full charge at 25°C
Approx. 1000 cycles of discharging down to 10% and full charging
Not possible to replace battery
Stored program system
35 basic
38 advanced
1.65 ms (1000 steps) See page A-1.
0.64 ms (not including expansion I/O service, clock function processing, data
link processing, and interrupt processing) See page A-2.
256
64
400
32
32
3 to 15 ms (selectable in increments of 1 ms)
Four inputs (I2 through I5) can be designated as catch inputs or interrupt inputs
Minimum turn on pulse width: 40 µs maximum
Minimum turn off pulse width: 150 µs maximum
Power failure, watchdog timer, data link connection, user program EEPROM sum
check, timer/counter preset value sum check, user program RAM sum check,
keep data, user program syntax, user program writing, CPU module, clock IC, I/O
bus initialize, user program execution
Turning power on and off
Start/stop command in WindLDR
Turning start control special internal relay M8000 on and off
Turning designated stop or reset input off and on
Output
Keep Type
Operating
Operating
OFF
Unchanged
OFF
OFF/Reset to zero
Unchanged
Unchanged
« FC4A M
S
ICRO
MART
FC4A-C16R2
FC4A-C16R2C
15,000 bytes
(2,500 steps)
9
7
35 basic
40 advanced
1024
128
1300
100
100
Internal Relay, Shift Register,
Counter, Data Register
Clear Type
Operating
Unchanged
OFF/Reset to zero
OFF/Reset to zero
U
'
M
»
SER
S
ANUAL
FC4A-C24R2
FC4A-C24R2C
27,000 bytes
(4,500 steps)
4 modules
14
Expansion:
64
10
35 basic
48 advanced
1024
128
1300
100
100
Timer Current Value
Operating
Unchanged
Reset to zero
Reset to preset

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents