Programming WindLDR

In the 1:1 computer link system, a computer can be connected to either port 1 or 2 on the
1:N computer link system, a computer must be connected to port 2 on the CPU module and every CPU module must have
a unique device number 0 through 31. The Communication page in the Function Area Settings must be programmed for
each station in the computer link system. If required, communication parameters can also be changed.
Since these settings relate to the user program, the user program must be downloaded to the
any of these settings.
1. From the
WindLDR
appears.
2. Click the Communication tab, and select Maintenance Protocol in the Port 1 or 2 pull-down list.
3. Click the Configure button. The Communication Parameters dialog box appears. Change settings, if required.
Note: Only when the mode selection input is turned on, the selected communication parameters are enabled.
Otherwise, default communication parameters take effect; 9600 bps, 7 data bits, even parity, 1 stop bit,
receive timeout 500 msec.
4. Click the OK button.
26-2
C
OMMUNICATION
menu bar, select Configure > Function Area Settings. The Function Area Setting dialog box
« FC4A M
Baud Rate (bps)
Data Bits
Parity
Stop Bits
Receive Timeout (ms)
Device Number
Mode Selection Input
S
U
'
M
ICRO
MART
SER
S
ANUAL
CPU module. In the
MicroSmart
MicroSmart
1200, 2400, 4800, 9600, 19200
7 or 8
None, Odd, Even
1 or 2
10 to 2540 (10-msec increments)
(Receive timeout is disabled when 2550
is selected.)
0 to 31
Any input number
»
after changing