AS-Interface Power Supply
The AS-Interface bus uses a dedicated 30V DC power supply (AS-Interface power
supply), which is indicated with the AS-Interface mark. General-purpose power sup-
ply units cannot be used for the AS-Interface bus.
• Use a VLSV (very low safety voltage) to power the AS-Interface bus.
Caution
The normal output voltage of the AS-Interface power supply is 30V DC.
Recommended IDEC AS-Interface Power Supplies
Input Voltage
100 to 240V AC
Cables
The AS-Interface bus uses only one cable to transmit signals and power. Use one of the following cable types (the wire
does not have to be stranded).
• Standard yellow unshielded AS-Interface cable (with polarity)
• Ordinary two-wire flat cable
Applicable Cable Specifications
Cable Type
AS-Interface
Standard Cable
2-wire Flat Cable
or
Single Wires
(See Note)
Note: When using single wires, the maximum cable length is 200 mm. See "Maximum Communication Distance" on page
28-1.
Output Voltage
30.5V DC
AS-Interface Cable
Cable Size/Manufacturer
Cable sheath color:
Conductor cross section:
LAPP's Cables
Type No: 2170228 (sheath material EPDM)
Type No: 2170230 (sheath material TPE)
Conductor cross section
Stranded wire:
0.5 to 1.0 mm
Solid wire:
0.75 to 1.5 mm
AWG:
20 to 16
« FC4A M
ICRO
28: AS-I
NTERFACE
Output Wattage
73W
145W
Yellow
2
1.5 mm
2
2
S
U
'
M
»
MART
SER
S
ANUAL
M
C
ASTER
OMMUNICATION
AS-Interface Marks
Type No.
PS2R-Q30ABL
PS2R-F30ABL
Two-wire Flat Cable
Cross-sectional View
AS-Interface –
AS-Interface +
(blue)
(brown)
AS-Interface –
AS-Interface +
(blue)
(brown)
28-3