IDEC SE9Z-HC Instruction Manual

Handy controller exclusive for se4d series.

Advertisement

Quick Links

B-1430(0)
INSTRUCTION MANUAL
Handy Controller Exclusive for SE4D Series
SE9Z-HC
F U
N C
T I O
N
C A
N C
E L
E N
T E
R
MJE-SE9ZHC No.0027-96V

Advertisement

Table of Contents
loading

Summary of Contents for IDEC SE9Z-HC

  • Page 1 B-1430(0) INSTRUCTION MANUAL Handy Controller Exclusive for SE4D Series SE9Z-HC T I O - + MJE-SE9ZHC No.0027-96V...
  • Page 2 (MEMO)
  • Page 3 4) Though we have carefully drawn up the contents of this instruction manual, if there are any aspects that are not clear, or any error that you may notice, please contact our local IDEC office or the nearest distributor.
  • Page 4: Table Of Contents

    Contents CHAPTER 1 INTRODUCTION ................4 Attention Marks ..................... 4 Safety Precautions ....................4 CHAPTER 2 GENERAL OUTLINE ...............6 Features ........................ 6 Part Descriptions ....................6 Connecting / Setting Procedures ................7 CHAPTER 3 FUNCTIONS ..................8 Functional Descriptions ..................8 3-1-1 Fixed Blanking Function..................8 3-1-2 Floating Blanking Function.................9 3-1-3 Auxiliary Output Switching Function..............10 3-1-4 Emission Intensity Control Function..............11...
  • Page 5: Chapter 1 Introduction

    CHAPTER 1 INTRODUCTION Attention Marks This instruction manual employs the following attention marks depending on the degree of the danger to call operator’s attention to each particular action. Read the following explanation of these marks thoroughly and observe these notices without fail. Besides, the attention mark is prepared for the helpful information, detail instruction related to each part, and reference item or page.
  • Page 6 INTRODUCTION ♦ Fixed blanking function, floating blanking function ● With the fixed blanking function, this device prevents the person or object from entering into the dangerous parts of the machine through the invalid sensing area. However, even though this device can prevent the interference of the person or object into the invalid sensing area with the fixed blanking function, there might exist the more space between the SE4D series and already-existence object.
  • Page 7: Chapter 2 General Outline

    CHAPTER 2 GENERAL OUTLINE This chapter gives the system construction, part description, etc. of this device. Features This device is the handy controller for setting each function of the light curtain SE4D series. Besides, this device performs the checking and copying the setting contents of the function, and protection of writing.
  • Page 8: Connecting / Setting Procedures

    Connecting / Setting Procedures Connecting / Setting Procedures This section describes the connecting / setting procedures for both this device and SE4D series. 1. Set the SE4D series, and check that the 2. Turn OFF the power and connect this SE4D series works properly.
  • Page 9: Chapter 3 Functions

    CHAPTER 3 FUNCTIONS Functional Descriptions If configuration of the system is changed (replace the SE4D series etc.), set the function again. 3-1-1 Fixed Blanking Function This is a function that the control output (OSSD 1 / 2) of SE4D series is not turned OFF, even if the specified beam channel(s) is blocked OFF.
  • Page 10: Floating Blanking Function

    Functional Descriptions 3-1-2 Floating Blanking Function This function is set in each SE4D series. If the number of the blocked beam channels is less than the set number of the beam channels, the control output (OSSD 1 / 2) of SE4D series is not turned “OFF.” This function is useful when an obstacle moves within the sensing area.
  • Page 11: Auxiliary Output Switching Function

    Functional Descriptions <Minimum sensing object> Floating blanking function Effective Ineffective 1 beam channel 2 beam channels 3 beam channels SE4D-H□ ø25mm ø45mm ø65mm ø85mm If the floating blanking function is used, the incident light intensity indicator is turned OFF when an obstacle exists in the sensing range regardless of the incident light intensity. 3-1-3 Auxiliary Output Switching Function This function changes the operation state of the auxiliary output.
  • Page 12: Emission Intensity Control Function

    Functional Descriptions 3-1-4 Emission Intensity Control Function This function reduces the emitting intensity. It is useful for preventing interference from the emitter to the other devices. Emission intensity control • CLR (Ineffective) : Operating range is 0.3 to 9m for SE4D-H□ (12 to 64 beam channels), 0.3 to 7m for SE4D-H□...
  • Page 13: Interlock Setting Changing Function

    Functional Descriptions Muting input conditions ● The order for inputting the muting input A and B, which the muting function activates, can be set. A = b: Effective even either comes first b: Effective only when the input A comes first A: Effective only when the input B comes first Note: The setting is possible for each channel.
  • Page 14: Protective Function

    Functional Descriptions 3-1-9 Protective Function The functional settings are not allowed to change without the input of a password. When the protective function is set to “effective,” the setting can be changed by inputting the password. The setting contents monitor function can be used regardless of the protective function “effective / ineffective.” The password should be a 4-digit number from 0 to 9.
  • Page 15: Function Setting (Operation Procedure)

    Function Setting Function Setting (Operation Procedure) This section describes the setting of each function (operation procedure). <Selecting the setting item> Select a setting item with FUNCTION or CANCEL switch, and confirm it with ENTER. key operation : FUNCTION To “3-2-1 Fixed Blanking Function” * * * * : ENTER : CANCEL...
  • Page 16 Function Setting <Inputting a password> When the protective function is effective, “Lock” is shown on the lower section of the digital display. The functional settings of the SE4D series cannot be changed unless the password is input. Note that “3-2-9 Protective Function” is “locked” even when the protective function is ineffective. 1) “3-2-11 Setting Contents Monitoring Function”...
  • Page 17 Function Setting <Selecting sensor> Each function can be set on each SE4D series connected in series as well. Select a SE4D series to set each function. Since “3-2-5 Copy Function” and “3-2-9 Protective Function” are set collectively, it is not necessary to select a sensor.
  • Page 18: Fixed Blanking Function

    Function Setting 3-2-1 Fixed Blanking Function 1. Fixed blanking Select function Select sensor function (Clear setting) Send Input To 1 password (Ineffective) (All sensors) 2. To Floating (Clear setting) blanking function (Error) (Main sensor) Select sensor Check result (Auto setting) Send (Effective) (Auto setting)
  • Page 19: Floating Blanking Function

    Function Setting 3-2-2 Floating Blanking Function 2. Floating blank- Sensor selection Set No. of beam channel ing function Send (Note) Input To 2 password (All sensors) (Ineffective) 3. To Auxiliary output switching function (Error) (Main sensor) Ineffective setting Setting both ends non-serial beam beam channels...
  • Page 20: Auxiliary Output Switching Function

    Function Setting 3-2-3 Auxiliary Output Switching Function 3. Auxiliary output Select output switching function Send Input pass- To 3 word (*) (Mode 0) 4. To Emission intensity control function (Error) (Mode 1) (Mode 2) key operation ・ ・ : FUNCTION ・...
  • Page 21: Emission Intensity Control Function

    Function Setting 3-2-4 Emission Intensity Control Function 4. Emission intensity con- Select sensor Emission intensity control Send trol function Input To 4 pass- word (All sensors) (Effective) 5. To Copy function (Error) (Main sensor) (Ineffective) key operation : FUNCTION (Sub sensor 1) : ENTER : CANCEL (Sub sensor 2)
  • Page 22: Copy Function

    Function Setting 3-2-5 Copy Function key operation Confirm function Select function 5. Copy function of system device Receive : FUNCTION Input : ENTER password * * * * To 5 : CANCEL (Upload) 6. To Muting setting changing function (Error) Check function Receive * * * *...
  • Page 23: Muting Setting Changing Function

    Function Setting 3-2-6 Muting Setting Changing Function 6. Muting setting Beam channel No. Muting lamp diagnosis Select beam changing Muting setting Select sensor channel setting (Note 2) function MENU setting Input password First beam chan- Effective beam (Effective) (Initialize) (Note 1) A←→B in nel is effective channel...
  • Page 24 Function Setting *: The functional setting of each beam channel is as follows. on : The muting function is effective. oFF : The muting function is ineffective. ● CLR initializes the all settings. (factory setting) • All beam channels: Effective •...
  • Page 25: Interlock Setting Changing Function

    Function Setting 3-2-7 Interlock Setting Changing Function 7. Interlock setting Setting selection Send changing function Input To 7 password (Mode 0) 8. To External device monitor setting changing function (Error) (Mode 1) key operation : FUNCTION (Mode 2) : ENTER : CANCEL (Mode 3) *: When two or more SE4D series are connected, cancel the protective function of all SE4D series.
  • Page 26: External Device Monitor Setting Changing Function

    Function Setting 3-2-8 External Device Monitor Setting Changing Function 8. External device monitor setting Relay monitor setting changing function Send Input pass- To 8 word (Ineffective) Time setting 9. To Sub display function / Protect function (Error) (Effective) (100ms) (110ms) (120ms) key operation ・...
  • Page 27: Protective Function

    Function Setting 3-2-9 Protective Function key operation 9. Sub display function / Pro- : FUNCTION Select sensor Select function tect function : ENTER Input : CANCEL password Send (All sensors) (Ineffctive) To 9 10. To Sub dis- play function / Initialization function (Main sensor) (Eeffctive)
  • Page 28: Initialization Function

    Function Setting 3-2-10 Initialization Function 10. Sub display function / Initialization Select sensor Confirm Send function Input To 10 password (All sensors) 11. To Sub dis- play function / Setting con- (Error) tents moni- toring function (Main sensor) key operation : FUNCTION (Sub sensor 1) : ENTER...
  • Page 29: Setting Contents Monitoring Function

    Function Setting 3-2-11 Setting Contents Monitoring Function 11. Sub display function / Set- ting contents Fixed blanking Detail display monitoring Select sensor function (Only for SET) function (Main sensor) Fixed blanking (Current setting) (Effective) 12. To Sub display function function / Over- ride setting Floating blanking Detail display...
  • Page 30: Override Setting Changing Function

    Function Setting 3-2-12 Override Setting Changing Function 12. Override setting Time setting changing function Send Input pass- To 12 word (60 sec.) 9. To Sub display function / Protect function (Error) (70 sec.) (80 sec.) key operation ・ ・ : FUNCTION ・...
  • Page 31: Chapter 4 Troubleshooting

    CHAPTER 4 TROUBLESHOOTING Symptoms Cause Remedy Control output (OSSD This device is connected to the SE4D Disconnect this device. 1 / 2) is not turned ON. series. Error indication Cause Remedy The fixed blanking function is set in all Do not set the fixed blanking function in all l i g h t s r e c e i v e d / a l l l i g h t s b l o c k e d lights received / all lights blocked condition, condition, or the muting function is set in...
  • Page 32: Chapter 5 Specifications / Dimensions

    CHAPTER 5 SPECIFICATIONS / DIMENSIONS Specifications Model No. SE9Z-HC Item Applicable model Light curtain SE4D series Supply voltage 24V DC±10% Ripple P-P 10% or less (common to sensor power supply) Current consumption 65mA or less Communication method RS-485 two-way communications (specific procedure) Digital display 4-digit red LED display ×...
  • Page 33 Revision history First edition January 10, 2012...
  • Page 34 (MEMO)
  • Page 35 (b) which are used outdoors or in environments subject to any likelihood of chemical contamination or electromagnetic influence; (c) which are likely to be used beyond the limits of operations or environments specified by IDEC in the catalogue or otherwise;...
  • Page 36 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan IDEC ELEKTROTECHNIK GmbH Wendenstrasse 331, D-20537, Hamburg, Germany http://www.idec.com 2012.2...

Table of Contents