Chapter 16
Subheading
SHT-DCSW
ADJ-VPP
AST-SEL
REGM-SEL
ADJ-BLNK
2TR-RVON
USB-RCNT
16-222
COPIER>OPTION>BODY
Skip the DCON termination processing when executing shutdown.
Setting range
0: Execute shutdown after the DCON fan control is terminated.
1: Execute shutdown before the DCON fan control is terminated.
Standard value
0
Adjust the developing bias Vpp.
Function to adjust Vpp for the developing AC bias.
Setting range
-4 to 2
Standard value
0
Change the range of the advanced smoothing.
AST-SEL (AST level SELect)
Setting range
0 to 3
Standard value
2
Change the range of the thin line density correction.
REGM-SEL (REos GaMma SELect)
Setting range
0 to 4
Standard value
2
Adjust the length of the developing bias blank.
Function to adjust the blank length of the developing bank pulse bias
Setting range
1 to 4
Standard value
3
Set ON/OFF of the weak bias of the trail edge of paper.
Set this mode to ON when scattering occurred to the trail edge of the image on the 2nd side in 1/
3 speed.
Setting range
0: OFF
1: ON
Standard value
0
Auto-connection setting at disconnection of USB device (USB RECONNECT)
Setting range
0 to 1
0: Non auto-connect
1: Auto-connect
Standard value
0