4 AUXILIARY AND APPLIED FUNCTIONS

4.7.2 Access range of the communications via network

<Example>
Personal
computer
(1) Network configuration via the MELSECNET/10(H) or the Ethernet
(a) It can access the other CPU via the network from the programming software
packages (GX Developer, MT Developer, etc.) of the personal computer
connected with the CPU or serial communication module in USB/RS-232.
(b) It can access the other CPU via the network from the programming software
packages in the personal computer by connecting the personal computer
equipped with Ethernet to MELSECNET/10(H) or Ethernet board to the
Ethernet to MELSECNET/10(H) or Ethernet.
(c) The access range of above (1) and (2) can be accessed to 8 network points
by setting the routing parameter to the control CPU of the network module
and the CPU which connected the personal computer.
Personal
computer
USB/
RS-232
RS-232
QnUD(H)
Q173D
C24
MNET
CPU
CPU
or
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
Network No.4
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
Network No.8
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
: Communication is possible
: Communication is possible (Setting of the routing parameter is necessary.)
: Communication is impossible
Personal computer
MNET board or Ether
Network No.1
QnUD(H)
Q173D
MNET
CPU
CPU
or
Ether
Network No.3
QnUD(H)
Q173D
MNET
CPU
CPU
or
Ether
Network No.5
QnUD(H)
Q173D
MNET
CPU
CPU
or
Ether
Network No.7
QnUD(H)
Q173D
MNET
CPU
CPU
or
Ether
Network No.9
QnUD(H)
Q173D
MNET
CPU
CPU
or
Ether
4 - 28
C24
: Serial communication module
MNET
: MELSECNET/10(H)
Ether
: Ethernet
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
QnUD(H)
Q173D
MNET
MNET
CPU
CPU
or
or
Ether
Ether
Network
No.2
Network
No.6
Network
No.10

Advertisement

Table of Contents

   Also See for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

   Related Manuals for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

This manual is also suitable for:

Q173dcpu

Comments to this Manuals

Symbols: 0
Latest comments:
  • p Dec 14, 2015 07:47:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by ...
  • p Dec 14, 2015 07:32:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by