HPE FlexNetwork HSR6800 Security Command Reference page 72

Hide thumbs Also See for FlexNetwork HSR6800:
Table of Contents

Advertisement

Default command level
2: System level
Parameters
radius-scheme radius-scheme-name: Specifies buffered stop-accounting requests that are
destined for the accounting server defined in a RADIUS scheme. The RADIUS scheme name is a
case-insensitive string of 1 to 32 characters.
session-id session-id: Specifies the stop-accounting requests buffered for a session. The session
ID is a string of 1 to 50 characters.
time-range start-time stop-time: Specifies the stop-accounting requests buffered in a time range.
The start time and end time must be in the format HH:MM:SS-MM/DD/YYYY or
HH:MM:SS-YYYY/MM/DD.
user-name user-name: Specifies the stop-accounting requests buffered for a user. The username is
a case-sensitive string of 1 to 80 characters. Whether the user-name argument should include the
domain name depends on the setting configured by the user-name-format command for the
RADIUS scheme.
slot slot-number: Specifies a card by its slot number. The slot-number argument represents the slot
number of the card. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The
chassis-number argument represents the member ID of the IRF member device, and the
slot-number argument represents the slot number of the card. (In IRF mode.)
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
If the device sends a stop-accounting request to a RADIUS server but receives no response, it
retransmits it up to a certain number of times (defined by the retry command). If the device still
receives no response, it considers the stop-accounting attempt a failure, buffers the request, and
makes another stop-accounting attempt. The maximum number of the stop-accounting attempts is
defined by the retry stop-accounting command. If all attempts fail, the device discards the request.
Examples
# Display information about the stop-accounting requests buffered for user abc. (In standalone
mode.)
<Sysname> display stop-accounting-buffer user-name abc slot 0
Slot
0:
RDIdx Session-ID
1
1000326232325010
1
1000326232326010
Total 2 record(s) Matched
# Dsplay information about the stop-accounting requests buffered for user abc on slot 0 of IRF
member 1. (In IRF mode.)
<Sysname> display stop-accounting-buffer user-name abc chassis 1 slot 0
Slot
0 in chassis
RDIdx Session-ID
1
1000326232325010
user name
abc
abc
1:
user name
abc
59
Happened time
23:27:16-08/31/2006
23:33:01-08/31/2006
Happened time
23:27:16-08/31/2006

Advertisement

Table of Contents
loading

Table of Contents