Reset Portal Connection Statistics - HPE FlexNetwork HSR6800 Security Command Reference

Hide thumbs Also See for FlexNetwork HSR6800:
Table of Contents

Advertisement

undo portal server server-name user-sync
Default
The portal user synchronization function is not configured.
Views
System view
Default command level
2: System level
Parameters
server-name: Name of a portal server, a case-sensitive string of 1 to 32 characters. The specified
portal server must have existed.
user-sync: Enables the portal user synchronization function.
interval interval: Specifies the interval at which the device checks the user synchronization packets.
The interval argument ranges from 60 to 3600 and defaults to 300, in seconds.
retry retries: Specifies the maximum number of consecutive failed checks. The retries argument
ranges from 1 to 5 and defaults to 4. If the access device finds that one of its users does not exist in
the user synchronization packets from the portal server within N consecutive probe intervals (N =
retries), it considers that the user does not exist on the portal server and logs the user off.
Usage guidelines
The user information synchronization function requires that a portal server supports the portal user
heartbeat function (currently only the IMC portal server supports portal user heartbeat). To
implement the portal user synchronization function, you also need to configure the user heartbeat
function on the portal server and make sure that the user heartbeat interval configured on the portal
server is shorter than or equal to the synchronization probe interval configured on the device.
Deleting a portal server on the device will delete the portal user synchronization configuration with
the portal server.
If you configure the user synchronization function for a portal server for multiple times, the last
configuration takes effect. If you do not specify an optional parameter, the default setting of the
parameter is used.
For redundant user information on the device—information of the users considered as nonexistent
on the portal server, the device deletes the information during the (N+1)th probe interval, where N
equals to the value of retries configured in the portal server user-sync command.
Examples
# Configure the device to synchronize portal user information with portal server pts:
Setting the synchronization probe interval to 600 seconds
Specifying the device to log off users if information of the users does not exist in the user
synchronization packets sent from the server in two consecutive probe intervals.
<Sysname> system-view
[Sysname] portal server pts user-sync interval 600 retry 2

reset portal connection statistics

Use reset portal connection statistics to clear portal connection statistics on a specific interface or
all interfaces.
Syntax
reset portal connection statistics { all | interface interface-type interface-number }
169

Advertisement

Table of Contents
loading

Table of Contents